According to the IFC, existing opening protectives for floors and shafts
| | | | | | | | | | |
are permitted to employ fusible links where the link temperature does
| | | | | | | | | | |
not exceed _____ degree F. - CORRECT ANSWER✔✔-135
| | | | | | |
Exterior walls of a Group S-1 aircraft hanger within 20 feet of a public
| | | | | | | | | | | | | |
way or lot line must have a fire-resistance rating of not less than ____
| | | | | | | | | | | | | |
hours. - CORRECT ANSWER✔✔-2
| | |
When an installation subject to inspection prior to use is covered or
| | | | | | | | | | | |
concealed without having been inspected, fire code official has the
| | | | | | | | | |
authority to ____. - CORRECT ANSWER✔✔-Require the work be
| | | | | | | | |
exposed for inspection | |
In a new construction, nonstructural projections such as trim and similar
| | | | | | | | | |
|decorative features are permitted to project into the required egress
| | | | | | | | | |
width not more than ____ inches on each side. - CORRECT ANSWER✔✔-
| | | | | | | | | | |
1-1/2
In new construction, stairways in a nonsprinklered building that are part
| | | | | | | | | |
|of the accessible means of egress for the exterior area for assisted
| | | | | | | | | | | |
, rescue shall be not less than ___ inches between handrails. - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-48
In new construction, doors opening onto a ramp landing in the means of
| | | | | | | | | | | |
|egress shall not reduce the clear width to less than____ inches. -
| | | | | | | | | | | |
CORRECT ANSWER✔✔-42 |
All of the following are allowed as methods of serving a notice of
| | | | | | | | | | | | |
violation except___. - CORRECT ANSWER✔✔-Phone call from the code
| | | | | | | | |
official to the violator
| | |
When the fire code official observes a violation, a written notice of
| | | | | | | | | | | |
violation shall be prepared. After the notice is served and the
| | | | | | | | | | |
responsible person has not complied within the time specified, the next
| | | | | | | | | | |
course of action would be for _____. - CORRECT ANSWER✔✔-the fire
| | | | | | | | | | |
code official to request legal counsel to institute appropriate legal
| | | | | | | | | |
procedures
Where approved by the fire code official, the ratio of trained crowed
| | | | | | | | | | | |
managers required for facilities or events where more than, 1,000
| | | | | | | | | |
persons congregate may be reduced where the facility is equipped with
| | | | | | | | | | |
which of the following? - CORRECT ANSWER✔✔-Fire protection
| | | | | | | |
warranting a reduction | |
Questions With Correct Answers
According to the IFC, existing opening protectives for floors and shafts
| | | | | | | | | | |
are permitted to employ fusible links where the link temperature does
| | | | | | | | | | |
not exceed _____ degree F. - CORRECT ANSWER✔✔-135
| | | | | | |
Exterior walls of a Group S-1 aircraft hanger within 20 feet of a public
| | | | | | | | | | | | | |
way or lot line must have a fire-resistance rating of not less than ____
| | | | | | | | | | | | | |
hours. - CORRECT ANSWER✔✔-2
| | |
When an installation subject to inspection prior to use is covered or
| | | | | | | | | | | |
concealed without having been inspected, fire code official has the
| | | | | | | | | |
authority to ____. - CORRECT ANSWER✔✔-Require the work be
| | | | | | | | |
exposed for inspection | |
In a new construction, nonstructural projections such as trim and similar
| | | | | | | | | |
|decorative features are permitted to project into the required egress
| | | | | | | | | |
width not more than ____ inches on each side. - CORRECT ANSWER✔✔-
| | | | | | | | | | |
1-1/2
In new construction, stairways in a nonsprinklered building that are part
| | | | | | | | | |
|of the accessible means of egress for the exterior area for assisted
| | | | | | | | | | | |
, rescue shall be not less than ___ inches between handrails. - CORRECT
| | | | | | | | | | | |
ANSWER✔✔-48
In new construction, doors opening onto a ramp landing in the means of
| | | | | | | | | | | |
|egress shall not reduce the clear width to less than____ inches. -
| | | | | | | | | | | |
CORRECT ANSWER✔✔-42 |
All of the following are allowed as methods of serving a notice of
| | | | | | | | | | | | |
violation except___. - CORRECT ANSWER✔✔-Phone call from the code
| | | | | | | | |
official to the violator
| | |
When the fire code official observes a violation, a written notice of
| | | | | | | | | | | |
violation shall be prepared. After the notice is served and the
| | | | | | | | | | |
responsible person has not complied within the time specified, the next
| | | | | | | | | | |
course of action would be for _____. - CORRECT ANSWER✔✔-the fire
| | | | | | | | | | |
code official to request legal counsel to institute appropriate legal
| | | | | | | | | |
procedures
Where approved by the fire code official, the ratio of trained crowed
| | | | | | | | | | | |
managers required for facilities or events where more than, 1,000
| | | | | | | | | |
persons congregate may be reduced where the facility is equipped with
| | | | | | | | | | |
which of the following? - CORRECT ANSWER✔✔-Fire protection
| | | | | | | |
warranting a reduction | |