Assessment of the quality of the peripheral curves a. profile analyzer
(blends of a rigid contact lens) is achieved by the use of
the-
a. profile analyzer
b. shadow graph
c. keratometer
d. burton light


Contact lens power should be specified in- a. back vertex power
a. back vertex power
b. sphero-cylinder power
c. power in situ
d. posterier apical radius


The slit-lamp illumination that gives an overall view of the b. diffuse
cornea but limits detail is-
a. sclerotic scatter
b. diffuse
c. specular reflection
d. oscilatory

,When a keratometric miers reflected off a soft contact c. steep
lens are only clear when the wearer blinks, the lens fit is
too-
a. small
b. large
c. steep
d. flat


Transient keratometric mier distortion is usually due to- a. pre-ocular tear film abnormalities
a. pre-ocular tear film abnormalities
b. prolonged rigid lens wear
c. prolonged soft lens wear
d. irregular corneal astigmatism


Epithelial edema which manifests itself clinically as central a. the naked eye and an angle between the slit lamp beam and the eye of 90˚
corneal haze, is verified by the slit lamp using sclerotic
scatter illumination. What specific technique does the
examiner use to see this condition?
a. the naked eye and an angle between the slit lamp
beam and the eye of 90˚
b. the blue cobalt filter of the slit lamp and an angle of
about 45˚
c. the green filter of the slit lamp with high magnification
d. high magnification and an angle between the beam
and scope of 180˚


With a rigid contact lens in place a flourescein pattern d. with the rule astigmatism
shows a narrow bend horizontally wih a concentration of
flourescein inferiorly and superiorly under the lens.
Which one of the following type of astigmatism is
represented by this pattern?
a. lenticular astigmatism
b. residual astigmatism
c. against the rule astigmatism
d. with the rule astigmatism


Refractive Rx -3.00 -1.00 x 170 b. 180
K's 42.00 @ 170/43.00 @ 80
Given the above Rx and K's he following diagnostic toric
soft lens was used:
B.C. 8.8
Power -3.00 -1.00 x 180
During dianostic evalutation, the above lens rotated 10
clockwise. The lens ordered should have an axis of:
a. 10
b. 180
c. 170
d. 160

, Given the same circumstances from the above question, b. 10 clockwise rotation
once the correctly ordered lens has been dispensed, the
rotational marks should settle at ___ _.
a. 6 o clock
b. 10 clockwise rotation
c. 10 counter clockwise rotation
d. none of the above


An instrument that allows simultaneous verification of a. measuring magnifier
lens diameter, optic zone width, and peripheral curve (the book says d. radiuscope)
width is:
a. measuring magnifier
b. ophthalmometer
c. profile analyzer
d. radiuscope


The instrument used for magnification of the edge of a b. shadowgraph
rigid CL is a ___ _.
a. radiuscope
b. shadowgraph
c. profile analysis
d. keratometer


Mary is wearing in her right eye RGP lens with a base c. +250
curve of 43.50 and a power of +2.75. The doctor refracts
-0.75 sphere over this lens. If you wish to order her a new
lens with a curve of 43.00, what will the new power be?
a. +1.50
b. +2.00
c. +2.50
d. +3.00


Which of the following could be considered in the fitting d. 1, 2 and 3
of a keratoconus patient
1. aspheric
2. McGuire
3. Soper
4. tangent streak


a. 1 & 2
b. 2 & 3
c. 3 & 4
d. 1, 2 and 3

Geschreven voor

Instelling
ABO
Vak
ABO

Documentinformatie

Geüpload op
13 juni 2026
Aantal pagina's
16
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€15,74
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Briwisescore Stanford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
20
Lid sinds
2 jaar
Aantal volgers
5
Documenten
9901
Laatst verkocht
4 dagen geleden

1,7

3 beoordelingen

5
0
4
0
3
1
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen