ACI GRADE 1 TESTING WITH
COMPLETE SOLUTIONS

For concrete with aggregates less than 3 inches, the thermometer must remain in the
fresh concrete sample a. Minimum of 5 minutes or until temperature reading stabilizes.
(True or false) - ANSWER-False( 2 minutes but not more than 5)

The temperature measuring device must be accurate to within 0.1° ( true or false) -
ANSWER-False 1°F or 0.5°C

The temperature measuring device shall have a capacity of measuring temperature of
freshly mixed concrete throughout a range of ____ to ___F - ANSWER-30° to 120°F

A composite sample is not needed if only the temperature test is being run( T or F) -
ANSWER-True

The temperature of fresh concrete in a placement must be measured by inserting a
thermometer into the top six inches of concrete.( T or F) - ANSWER-False (does not
specify aggregate size)

ASTM C1064 states the container used to measure temperature of concrete must be
large enough to provide at least 5 inches of concrete. ( T or F) - ANSWER-False ( 3
inches or must be 3x the nominal max size)

The temperature of the concrete is recorded to the nearest __°F - ANSWER-1°F

Calibrate the temperature measuring device at least ___, or whenever there is a
question of accuracy - ANSWER-Annually

After the thermometer is placed in the concrete: - ANSWER-Gently press concrete
around the thermometer.

According to ASTM C1064, what is one reason to take the temperature of concrete? -
ANSWER-Verify conformance


The slump cone should be raised carefully, vertically upward, in a steady motion in
_____ seconds - ANSWER-3-7

The elapsed time between the start of filling the slump cone and the removal of the
cone must be more than: - ANSWER-2.5 minutes

, The slump should be measured to the nearest - ANSWER-quarter of an inch

In order to determine slump, you should measure the vertical distaance from -
ANSWER-The top of the mold to the displaced original center of the top surface.

The dimensions of the slump cone - ANSWER-Top diameter 4 inches, bottom diameter
8 inches, height 12 inches

In the slump test, if a decided falling away or shearing off the concrete from one side or
portion of the mass occurs upon raising the slump cone, one should - ANSWER-
Disregard the test and make a new test on another portion of the sample

The slump coke should be struck-off with: - ANSWER-The tamping rod

The slump cone must be placed: - ANSWER-On a flat moist, non-absorbent, rigid
surface

When rodding a second or third layer, the rod must penetrate the preceding layer by
about 1 inch (t or f) - ANSWER-True

The normal half cubic foot bucket may not be used to determine density(unit weight) of
lightweight concrete (t or f) - ANSWER-False

Concrete slump of less than 1 inch must be consolidated using a vibrator(t or f) -
ANSWER-True

According to ASTM C138, after rodding each layer, tap the sides of the container, with
the rod exactly 25 times. (T or F) - ANSWER-False

ASTM C138 states, "the minimum capacity of the bucket depends on the maximum
slump requirement." (T or F) - ANSWER-False

The outside of the density bucket should be cleaned before weighing. (T or F) -
ANSWER-True

Concrete with a slump Less than 1 inch should be riffed 25 times per layer (t or f) -
ANSWER-False ( using vibration)

According to C138, concretes with slumps of 1-3 inches may be compacted with the
vibrator or the rod. (T or F) - ANSWER-True

The unit weight bucket must be calibrated at least once a month. (T or F) - ANSWER-
False (often)

Geschreven voor

Instelling
ACI
Vak
ACI

Documentinformatie

Geüpload op
21 juni 2026
Aantal pagina's
7
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,81
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
DREAMYDUST

Maak kennis met de verkoper

Seller avatar
DREAMYDUST Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
1 jaar
Aantal volgers
0
Documenten
489
Laatst verkocht
3 weken geleden

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen