Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

CCRN Practice

Beoordeling
-
Verkocht
-
Pagina's
4
Cijfer
A+
Geüpload op
27-11-2023
Geschreven in
2023/2024

You are monitoring a patient with a pulmonary artery catheter. You are unable to measure the patient's pulmonary artery wedge pressure. To obtain a value that corresponds to the pulmonary artery wedge pressure, you check the: A. Right ventricular pressure B. Pulmonary artery diastolic pressure C. Pulmonary artery mean pressure D. Right atrial pressure - ANSB. Pulmonary artery diastolic pressure When you cannot obtain a pulmonary artery wedge pressure, use the pulmonary artery diastolic pressure to detect trends in the pulmonary artery wedge pressure. The pulmonary artery diastolic pressure is usually 1 to 4 mm/Hg higher than pulmonary artery wedge pressure. However, a patient with pulmonary disease has pulmonary artery diastolic pressure influenced by higher right heart pressures, which do not correlate with the pulmonary artery wedge pressure. (Recall that pulmonary artery wedge pressure is a measure of left-sided heart pressure). The right atrial and right ventricular pressures reflect right-sided, not left-sided, heart pressures. Use the pulmonary artery mean pressure to calculate pulmonary vascular resistance. You are monitoring a patient's pulmonary artery catheter. The pulmonary artery waveform spontaneously changes to a pulmonary artery wedge pressure waveform. Choose the correct intervention: A. Immediately pull the catheter back to the right atrium B. Monitor the patient for ventricular ectopy C. Inflate the balloon with 1.5 cc of air D. Check that the balloon is fully deflated - ANSD. Check that the balloon is fully deflated Your patient's hemodynamic parameters are: Right atrial pressure of 4 mm/Hg; pulmonary artery wedge pressure of 7 mm/Hg; systemic vascular resistance of 1,000 dynes/sec/cm-5; cardiac index of 3.5 L/minute; and left ventricular stroke work index of 20 beats/minute. The heart function that concerns you most is: A. Contractility B. Preload C. Cardiac output D. Afterload - ANSA. Contractility The normal value for a left ventricular stroke work index is 35 to 85 beats/minute. Your patient's abnormally low left ventricular stroke work index of 20 beats/minute reflects a problem with contractility in his or her left ventricle. Afterload is reflected in the systemic vascular resistance, preload in the pulmonary artery wedge pressure, and cardiac output in the cardiac index; these three values are within normal limits. You should be concerned that your patient's poor cardiac muscle contractility will lead to insufficient cardiac output. Observe your patient for fatigue, peripheral edema, and shortness of breath (SOB). Your patient's pulmonary artery catheter readings show: Right atrial pressure of 6 mm/Hg; pulmonary artery wedge pressure of 10 mm/Hg; cardiac output of 6 L/minute; and systemic vascular resistance of 1,700 dynes/sec/cm-5. Choose the I.V. infusion drug that will bring the abnormal value into the desired range: A. Nitroprusside B. Amrinone (INN)

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

CCRN Practice
You are monitoring a patient with a pulmonary artery catheter. You are unable to measure the
patient's pulmonary artery wedge pressure. To obtain a value that corresponds to the
pulmonary artery wedge pressure, you check the:
A. Right ventricular pressure
B. Pulmonary artery diastolic pressure
C. Pulmonary artery mean pressure
D. Right atrial pressure - ANSB. Pulmonary artery diastolic pressure
When you cannot obtain a pulmonary artery wedge pressure, use the pulmonary artery
diastolic pressure to detect trends in the pulmonary artery wedge pressure. The pulmonary
artery diastolic pressure is usually 1 to 4 mm/Hg higher than pulmonary artery wedge
pressure. However, a patient with pulmonary disease has pulmonary artery diastolic pressure
influenced by higher right heart pressures, which do not correlate with the pulmonary artery
wedge pressure. (Recall that pulmonary artery wedge pressure is a measure of left-sided heart
pressure). The right atrial and right ventricular pressures reflect right-sided, not left-sided,
heart pressures. Use the pulmonary artery mean pressure to calculate pulmonary vascular
resistance.

You are monitoring a patient's pulmonary artery catheter. The pulmonary artery waveform
spontaneously changes to a pulmonary artery wedge pressure waveform. Choose the correct
intervention:
A. Immediately pull the catheter back to the right atrium
B. Monitor the patient for ventricular ectopy
C. Inflate the balloon with 1.5 cc of air
D. Check that the balloon is fully deflated - ANSD. Check that the balloon is fully deflated

Your patient's hemodynamic parameters are: Right atrial pressure of 4 mm/Hg; pulmonary
artery wedge pressure of 7 mm/Hg; systemic vascular resistance of 1,000 dynes/sec/cm-5;
cardiac index of 3.5 L/minute; and left ventricular stroke work index of 20 beats/minute. The
heart function that concerns you most is:
A. Contractility
B. Preload
C. Cardiac output
D. Afterload - ANSA. Contractility
The normal value for a left ventricular stroke work index is 35 to 85 beats/minute. Your
patient's abnormally low left ventricular stroke work index of 20 beats/minute reflects a
problem with contractility in his or her left ventricle. Afterload is reflected in the systemic
vascular resistance, preload in the pulmonary artery wedge pressure, and cardiac output in the
cardiac index; these three values are within normal limits. You should be concerned that your
patient's poor cardiac muscle contractility will lead to insufficient cardiac output. Observe
your patient for fatigue, peripheral edema, and shortness of breath (SOB).

Your patient's pulmonary artery catheter readings show: Right atrial pressure of 6 mm/Hg;
pulmonary artery wedge pressure of 10 mm/Hg; cardiac output of 6 L/minute; and systemic
vascular resistance of 1,700 dynes/sec/cm-5. Choose the I.V. infusion drug that will bring the
abnormal value into the desired range:
A. Nitroprusside
B. Amrinone (INN)

Geschreven voor

Vak

Documentinformatie

Geüpload op
27 november 2023
Aantal pagina's
4
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€7,42
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
eustacemaina122

Maak kennis met de verkoper

Seller avatar
eustacemaina122 USIU
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
3 jaar
Aantal volgers
1
Documenten
519
Laatst verkocht
1 jaar geleden

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen