ABSA 4b Exam Latest Version. Warm Air Heating System Equipment In a warm air heating system the cold air return registers are located a) in exterior walls b) in interior locations c) under windows d) in floors e) in ceilings B The major disadvantage of an electric resistance coil furnace for warm air heating is a) the high cost of electricity b) the danger from electric shock c) the high cost of maintenance d) the large size of the furnace e) the location of electrical wiring A Lowboy furnaces are just over a) 1.0 m in height b) 0.8 m in height c) 1.4 m in height d) 1.6 m in height e) 1.2 m in height E The advantage of having duct furnaces instead of a large central furnace is a) less initial cost b) easier installation c) better control of heat in each zone of the building d) that they require less space e) lower maintenance costs C The power supply for an electric resistance coil furnace is a) 60 V b) 120 V c) 240 V d) 220 V e) 480 V C In a fin-coil heat exchanger the primary source of heat for the exchanger is

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

ABSA 4b Exam Latest Version.
Warm Air Heating System Equipment


In a warm air heating system the cold air return registers
are located
a) in exterior walls
b) in interior locations
c) under windows
d) in floors
e) in ceilings
B


The major disadvantage of an electric resistance coil furnace
for warm air heating is
a) the high cost of electricity
b) the danger from electric shock
c) the high cost of maintenance
d) the large size of the furnace
e) the location of electrical wiring
A


Lowboy furnaces are just over
a) 1.0 m in height
b) 0.8 m in height
c) 1.4 m in height
d) 1.6 m in height
e) 1.2 m in height
E


The advantage of having duct furnaces instead of a large
central furnace is
a) less initial cost
b) easier installation
c) better control of heat in each zone of the building
d) that they require less space
e) lower maintenance costs
C


The power supply for an electric resistance coil furnace is
a) 60 V
b) 120 V
c) 240 V
d) 220 V
e) 480 V
C


In a fin-coil heat exchanger the primary source of heat for
the exchanger is
a) steam or hot water

,b) gas
c) oil
d) solar
e) radiant
A


A type of directly fired space heater is
a) a unit heater
b) a floor furnace
c) a wall furnace
d) all of the above
e) none of the above
D


High efficiency furnaces and heaters range in annual fuel
utilization efficiency (AFUE) from
a) 94 - 98%
b) 80 - 95%
c) 70 - 75%
d) 60 - 70%
e) 50 - 60%
B


In high efficiency furnaces if the temperature of the flue
gas drops below 65 degrees C the
a) flue gas will condense
b) water vapour will condense
c) furnace burner will shut down
d) furnace burner will start up
e) furnace vent will close
B


In a pulse combination furnace the stated efficiency is
a) 94 - 98%
b) 80 - 95%
c) 70 - 75%
d) 60 - 70%
e) 50 - 60%
Warm Air Furnace Components and Maintenance
A


Heat exchangers in gas fired furnaces are made of
a) brass
b) copper
c) aluminum
d) steel
e) cast iron
D


Air filters can be divided into two groups
a) mechanical and rotating drum

,b) electronic and steam
c) dry and wet
d) steam and rotating drum
e) mechanical and electronic
E


Electronic filters will remove
a) all particles from the air
b) fine particles from the air
c) odour producing gases from the air
d) smoke from the air
e) all of the above
B


The perimeter loop system of furnace ducting is ideal for a
building with
a) no insulation in the walls
b) concrete walls
c) no basement
d) low head room in the basement
e) no cold air returns
C


Which of the following is a type of outlet in a warm air
heating system?
a) a grill
b) a register
c) a ceiling diffuser
d) a perforated panel
e) all of the above
E


Supply outlets should always be located
a) in walls
b) in floors
c) in ceilings
d) to best prevent cold drafts
e) in baseboards
D


In a warm air heating system, the heated air should enter the
rooms preferably via the
a) high wall registers on the inside wall
b) baseboard registers on the inside wall
c) baseboard registers on the outside wall
d) high wall registers on the outside wall
e) unit heaters on the outside wall
C


Sleeve bearings on furnace fans require
a) no lubrication

, b) grease every six months
c) a few drops of oil every six months
d) a few drops of oil monthly
e) flood lubrication
C


Furnace heat exchangers should be checked for corrosion
because
a) carbon monoxide could leak into the building
b) the holes reduce the furnace efficiency
c) cold air could leak into the building
d) too much air would enter the furnace
e) the air will become too dry for comfortable heating
A


Insufficient heat throughout a building is likely caused by
a) too high an air flow
b) insufficient heat input
c) poorly insulated ducting
d) a missing filter
e) poor humidity control
B


Rooms that are stuffy and dry are created by
a) poor air distribution
b) a low supply air temperature
c) too much ventilation air
d) poorly insulated ducts
e) none of the above
Ventilation and Air Filters
E


Actual ventilation rates may vary per person from
a) 0.5 to 0.6 cubic metres/min
b) 0.5 to 0.75 cubic metres/min
c) 0.2 to 1.2 cubic metres/min
d) 0.14 to 1.5 cubic metres/min
e) 1.0 to 1.5 cubic metres/min
D


Ventilation can be divided into two basic methods:
a) forced and natural
b) mechanical and natural
c) forced and mechanical
d) natural and warmed air
e) natural and cold air
B


Natural ventilation is improved by the use of a roof
a) ventilator
b) radiator

Geschreven voor

Vak

Documentinformatie

Geüpload op
11 april 2024
Aantal pagina's
132
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,00
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LectDeniz Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
21
Lid sinds
2 jaar
Aantal volgers
13
Documenten
4902
Laatst verkocht
6 maanden geleden
Lect Deniz Academic Resources Hub

Lect Aziim is a highly experienced academic tutor and dedicated content creator with a strong track record of developing comprehensive, high-quality study materials for a wide range of university courses across the globe. With years of experience in higher education support, he excels at transforming complex academic concepts into clear, structured, and easy-to-follow resources that enhance student understanding and confidence. He provides an extensive collection of well-researched and carefully organized documents across key disciplines, including nursing, medicine, and various science fields. His materials cover essential topics such as anatomy, physiology, pharmacology, clinical practice, and core scientific principles, making them highly valuable for both coursework and intensive exam preparation. Each document is thoughtfully designed to align with university standards and curricula, ensuring accuracy, relevance, and practical application. Lect Aziim’s work stands out for its clarity, depth, and attention to detail, offering students concise summaries, detailed explanations, and exam-focused content that supports effective revision. His commitment to academic excellence and student success is reflected in the consistency and reliability of his materials, making him a trusted resource for learners seeking to improve performance and achieve their academic goals.

Lees meer Lees minder
5,0

1 beoordelingen

5
1
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen