FDNY F-80 Fire Safety & Alarm Systems in Homeless Shelters Exam Questions With 100% Correct Answers.
FDNY F-80 Fire Safety & Alarm Systems in Homeless Shelters Exam Questions With 100% Correct Answers. GOOD As the F-80 C of F holder, you notice a minor defect in the fire protection system and report it to the building owner. In the event the issue is still not corrected three months later, what would be the next step that you are required to take? Report the defect in writing to the Fire Department GOOD Typical causes of fires in homeless shelters are considered which of the following? - Halogen lamps - Unattended and prohibited microwaves - Overloaded extension cords GOOD Shelter staff members shall be readily identifiable at all times while on duty by means of an approved identification such as a: - Nameplate - Cap, armband - Uniform Aisles spaces in shelters shall not be less than 36 inches in width, EXCEPT that cross aisles (aisle space in the main hallways) are required not to be less than how many inches in width? 48 inches 6.- ________________ involves using a keyed switch to recall the affected elevator bank non-stop to the lobby or sky lobby during a fire condition. ?????? Phase l Coordinators of Fire Safety & Alarm Systems in Homeless Shelters should be familiar with which of the following procedures while on duty? - Ensure that all required log books are updated and kept on the premises in a secure area. - Must receive training and be highly proficient on the Fire Alarm Control Panel. - Take proper steps upon the discovery of a fire protection system impairment. What type of fire extinguisher should be used if a kitchen grease fire starts in a homeless shelter? Class K What would be considered an example of an UNPLANNED OUT OF SERVICE CONDITION? - Break or major leak in the sprinkler system - Empty gravity tank - Inoperative or shut water supply valves If a fire alarm system is transmitted immediately after pulling down on the cover of a manual pull station, that person has used a _________ pull station. Single action station The clearance between the bottom of a portable fire extinguisher and the floor must be at least __________ inches. ??? 4 Who is responsible for the safety of all building occupants, reducing the threat of fires, and assisting with the evacuation via a safe stairwell in case of a fire emergency? They also hold a valid certificate of fitness for such purpose. Fire Guard If an emergency occurs, F-80 Certificate of Fitness holders are required to be trained and fully competent in which of the following? Operating the fire alarm control panel in the shelter in which they are employed. Before authorizing a system to go out of service which of the following shall be performed by the impairment coordinator? - Place out of service tags at all required and appropriate locations. - Notify the Fire Department and the responsible person. - Maintain the system in service until work is ready to begin. 18.-The ___________ function is used to check the status of the Light Emitting Diodes (LEDs) on the FACP. All of the lights on the panel must work.???? Lamp test The ____________ is a system installed in a specific area or floor for a specific purpose in a building that has a required base building fire alarm system. Activation of this system shall activate the audible and visual appliances and notify the Fire Department via the Central Station. Sub-System When a fire or non-fire related drill is taking place, the Coordinator of Fire Safety and Alarm Systems in Homeless Shelters and FEP staff should pay close attention to and address which of the following: -Identifying any problems with the fire alarm system. - Visually inspecting the building for any exit, stairway or hallway obstructions. - Difficulties experienced by people with disabilities or other special needs. 21.- The fire alarm system shall have a secondary power supply which provides power within _______ seconds of failure of the primary power supply.????? 10 The ____________ is designed to automatically activate the alarm when the room temperature increases at a rapid rate of 12-15 degrees Fahrenheit (F) per minute. Rate of rise heat detector What type of detector is designed to activate automatically when the detector components melt at a preset temperature level? Fixed temperature detector 24.- You are the Coordinator of Fire Safety and Alarm Systems on the daytime shift. The most recent drill conduced was on October 23. You must ensure that the next drill takes place on that same shift NO LATER than on which of the following dates???????? - November 23 of the same year Below grade areas in shelters that are not protected throughout the premises by a sprinkler system shall not be used for which of the following? - Gathering places - Recreation rooms - Lounges A ______________ is a device which initiates an alarm indicating a flow of water throughout the fire protection system. Sprinkler water flow detector Emergency preparedness plans must be reviewed and updated as required to reflect any significant changes in staff assignments, or the design and arrangement of the premises at a minimum once every __________. Year 15.-What feature activates all the audio/visual devices throughout the building when a fire is detected???? General alarm Method 5b.- A ____________ is a device that receives alarm signals from protected premises and re-transmits those signals to the Fire Department's Bureau of Fire Communication. ???? Central Station Transmitter Select the correct statement regarding the F-80 Certificates of Fitness: If the F-80 holder leaves a fully occupied shelter without designating a deputy F-80 C of F holder, the FDNY can revoke or suspend their C of F. 7b.- While conducting an emergency drill, the Coordinator of Fire Safety and Alarm Systems in Homeless Shelters and FEP staff should pay attention to which of the following EXCEPT ?????? Ensuring that the duration of the drill meets the timeframe required by the FDNY. Which of the following is NOT considered part of an audio or visual notification device? Pull station A manual pull station should be located approximately how many feet within an exit doorway when it is installed? Five In what type of buildings and occupancies are coordinators of Fire Safety and Alarm Systems In Homeless Shelters required? Any building or occupancy that is equipped with a one way voice communication system operated for more than 15 persons for a period of more than 30 days. You are the Coordinator of Fire Safety & Alarm Systems in a homeless shelter and are supervising the fire guards on duty. They started their first patrol at approximately 8:00 a.m. The fire guards are expected to patrol every area of the shelter again NO LATER than which of the following times? 9:00 a.m. the same day What type of fire extinguisher is most appropriate for combustible ordinary materials? Class A The Coordinator of Fire Safety and Alarm Systems must be competent in demonstrating all of the following while operating the fire alarm control panel (FACP) EXCEPT: Repairing the system when it malfunctions Which of the following statements is CORRECT regarding emergency drills in homeless shelters? Building occupants are required to participate in all emergency drills.
Geschreven voor
- Instelling
- FDNY F-80 Fire Safety & Alarm Systems in Homeless
- Vak
- FDNY F-80 Fire Safety & Alarm Systems in Homeless
Documentinformatie
- Geüpload op
- 15 april 2024
- Aantal pagina's
- 7
- Geschreven in
- 2023/2024
- Type
- OVERIG
- Persoon
- Onbekend
Onderwerpen
-
fdny f 80 fire safety alarm systems in homeless