Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Oil Burners License Test/Questions and well Analyzed Solutions/100% Pass Rate

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
25-04-2024
Geschreven in
2023/2024

Oil Burners License Test/Questions and well Analyzed Solutions/100% Pass Rate

Instelling
Vak

Voorbeeld van de inhoud

Oil Burners License
Test/Questions and well
Analyzed Solutions/100% Pass
Rate
The main function of the primary control is: - -Locking out on safety in
the event of flame failure

-Power must be provided to an electric blower control board on
terminals: - -L1 and L2

-Once a PSC motor starts - -The centrifugal switch turns off the
electricity to the capacitor and the start windings

-Materials who's electrons are so loosely bound that they can be
persuaded to move with very little pressure allowing electricity to flow
are called - -Conductors

-Oil burners can make CO even when no smoke is present - -True

-Corrosion in the flu pipe may occur if - -Flue gas temperature is below
the dewpoint and sulfur oxide's combine with water

-To avoid condensing and the flu pipe and oil fired appliance should
have a minimum growth stock temperature of - -350°F

-All persons assisting and working under the supervision of a person
holding a certificate as an oil burner technician must hold current
apprentice certificates issued by Department of fire services - -True

-What size pipe is used to cross connect tank outlets piping - -1/2 inch

-Fuel return piping from an appliance shall - -Enter the top of the tank

-Delayed ignition may be caused by - -Unvented pressure regulator

-Installation of oil safety valves and oil pressure reducing valve - -
Reduces the chance of a return line leak

-What is an installation - -Complete and ready for operation of any oil
burning appliance

-Energizing the ignition circuit during the entire burn cycle reduces - -
Ignition component life

, -Fuel can be transferred from a tank to an appliance by pressurizing the
tank - -False

-What device must be equipped with an air proving switch - -Both, draft
inducers and power-venters

-What is a safety control - -Any control used to prevent unsafe
operation of the controlled equipment

-A non-resident steam or hot water boiler having a minimum safety
relief valve capacity over 200,000 BTU/hr requires certificate of
inspection from the department of fire services - -Prior to the initial
firing, every 3 years after

-What is the closest distance a supply tank can be to the burner - -5
feet

-Doing a combustion pretest on and oil burning appliance will not tell
you anything this is why they generally are performed - -False

-What is the minimum oil supply line size for a residential system - -3/8
inch

-A cad cell primary control can lock out safety because - -All of the
above- dirty, faulty, not sensing flame

-As heating oil gets colder it's viscosity thickens: - -Increase

-The purpose of the oil burner nozzle is to: - -Atomize, pattern and
meter the oil

-The primary control must be capable of - -All of the above

-A decrease in CO2 with an increase in excess air will give a drop in
stack temperature - -True

-Minimum net stack temperature of above 350°F must be maintained - -
To avoid condensation and maintain draft

-The primary control must be capable of reacting to - -The presence or
absence of flame

-The two principal combustible elements in number two fuel oil are
nitrogen and carbon - -False

-If a stack type controller fails you must - -Replace it with an approved
type controller

-When wiring multiple circulators they should be wired in - -Parallel

Geschreven voor

Vak

Documentinformatie

Geüpload op
25 april 2024
Aantal pagina's
5
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€7,98
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Nurselucy2023

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
Nurselucy2023 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
2 jaar
Aantal volgers
0
Documenten
794
Laatst verkocht
5 maanden geleden

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen