Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NC Mechanical 1 Level 1 Test 100% Correct Answers Verified Latest 2024 Version

Beoordeling
-
Verkocht
-
Pagina's
17
Cijfer
A+
Geüpload op
03-07-2024
Geschreven in
2023/2024

NC Mechanical 1 Level 1 Test | 100% Correct Answers | Verified | Latest 2024 Version which of the following can inspect welds on steel I beams in a commercial structure: A. Building inspector B. Contractor C. Designed professional engineer D. Jose the weld - C See GS160D-1106 Outdoor heated pool covers shall be provided with a ________? - Class 1 vapor retardant cover Energy Code R403.10.3 In a residence, Total duct leakage shall be less than or equal to __ cfm per 100 sq/ft of conditioned floor area served by that system - 5 Energy Code R403.3.3.1 In a residence, Heat pumps having supplimentary electric-resistance heat shal have controls that, except during deforst, prevent heat operation when _____? - the heat pump compressor can meet the heating load Energy Code 403.1.2 In a residence, Heat pump lockout shall be set no lower than ____ and no higher than ____. - 35*F, 40*F Energy Code R403.1.2 Are return ducts inside semi-conditioned and conditioned spaces of a residence required to be insulated? - Not required, other than may be necessary Energy Code R403.3.1In a commercial occupancy, a thermostat is allowed to control multiple zones from one thermostat - False, each zone must be controlled by individual controls within that zone. *Review entire section Energy Code C403.4.1 Alamance county is in climate zone _____ - 4A Energy Code The minimum screen mesh size for a vent terminating to the outdoors in a residence is? - Not less than 1/4" M401.5 (Table) A hazardous exhaust system is required when ______, except in laboratories - see M510.2 An exhaust system is required when ____? - Equipment and processes in such areas produce or throw off dust or particles sufficently to float in the air, or which emit heat, odors, fumes, spray, gas or smoke in such quantities so as to be irritating or injurious to health and safety M502.1 The maximum opening size of a screen on an air intake can be no larger than ___ Inch. - 1/2 Table M401.5 Condensate waste and drain line sizes shall be no smaller than ____. - 3/4" M307.2.2 The slope of a condensate drain shall be no less than _____ inch per 12 inches - 1/8" M307.2.1 Can a portable space heater be used to provide space heating in a interio

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

NC Mechanical 1 Level 1 Test | 100% Correct
Answers | Verified | Latest 2024 Version
which of the following can inspect welds on steel I beams in a commercial structure:

A. Building inspector

B. Contractor

C. Designed professional engineer

D. Jose the weld - ✔✔C

See GS160D-1106



Outdoor heated pool covers shall be provided with a ________? - ✔✔Class 1 vapor retardant cover

Energy Code R403.10.3



In a residence, Total duct leakage shall be less than or equal to __ cfm per 100 sq/ft of conditioned floor
area served by that system - ✔✔5

Energy Code R403.3.3.1



In a residence, Heat pumps having supplimentary electric-resistance heat shal have controls that, except
during deforst, prevent heat operation when _____? - ✔✔the heat pump compressor can meet the
heating load

Energy Code 403.1.2



In a residence, Heat pump lockout shall be set no lower than ____ and no higher than ____. - ✔✔35*F,
40*F

Energy Code R403.1.2



Are return ducts inside semi-conditioned and conditioned spaces of a residence required to be
insulated? - ✔✔Not required, other than may be necessary

Energy Code R403.3.1

,In a commercial occupancy, a thermostat is allowed to control multiple zones from one thermostat -
✔✔False, each zone must be controlled by individual controls within that zone.

*Review entire section

Energy Code C403.4.1



Alamance county is in climate zone _____ - ✔✔4A

Energy Code



The minimum screen mesh size for a vent terminating to the outdoors in a residence is? - ✔✔Not less
than 1/4"

M401.5 (Table)



A hazardous exhaust system is required when ______, except in laboratories - ✔✔see M510.2



An exhaust system is required when ____? - ✔✔Equipment and processes in such areas produce or
throw off dust or particles sufficently to float in the air, or which emit heat, odors, fumes, spray, gas or
smoke in such quantities so as to be irritating or injurious to health and safety

M502.1



The maximum opening size of a screen on an air intake can be no larger than ___ Inch. - ✔✔1/2

Table M401.5



Condensate waste and drain line sizes shall be no smaller than ____. - ✔✔3/4"

M307.2.2



The slope of a condensate drain shall be no less than _____ inch per 12 inches - ✔✔1/8"

M307.2.1



Can a portable space heater be used to provide space heating in a interior space intended for human
occupancy? - ✔✔No. Heating systems need to be permanently affixed.

, M309.1



Space heating systems need to be capable of maintaining a temperature of ____*F - ✔✔68

M309.1



Which requires a carbon monoxide to be installed?

A. A heat pump changeout

B. Gas Stove installation

C. Radiant Heater - ✔✔B; "...where fuel fired appliances or fireplaces are added or replaced..."

M313.2



Supply air to a swimming pool and associated deck areas shall not be recirculated unless such air is
_______? - ✔✔dehumidified to maintain the relative humidity of the area at 60% or less

M403.2.1 #2



the "Breathing Zone" is defined as the region within an occupied space between planes ___ inches and
___ inches above the floor and ___ feet from the walls of the space or from fixed air conditioning
equipment. - ✔✔3", 72", 2'

Definition in Mechanical Code



Appliances located in public garages shall be installed no lower than ______. - ✔✔1' higher than the
tallest vehicle garage door opening



a suspended air handler in a residential crawl space shall be no less than ___ inches above the adjoining
grade - ✔✔6"

M304.10.2



Fuel oil piping supports shall be in accordance with section ____ - ✔✔M305

M1304.1

Geschreven voor

Vak

Documentinformatie

Geüpload op
3 juli 2024
Aantal pagina's
17
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€7,97
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
hov
1,0
(2)

Maak kennis met de verkoper

Seller avatar
hov State University Of West Georgia
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
12
Lid sinds
2 jaar
Aantal volgers
3
Documenten
2125
Laatst verkocht
2 maanden geleden
Academic Avengers

Expert Verified Exams {Latest Versions} 99% Pass Rate

1,0

2 beoordelingen

5
0
4
0
3
0
2
0
1
2

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen