HVAC JOURNEYMAN EXAM /TEST EXAM WITH OVER 300 QUESTIONS AND CORRECT ELABORATED ANSWERS ALREADY RATED BY EXPERTS AS THE BEST EXAM (GRADED A+) A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire rated wall (C)interior wall (D)corridor wall - ANSWER- Corridor wall (IMC 607.5.4) Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' - ANSWER- 14' (IMC 603.6.1.1) The maximum vertical distance between the front lower lip of a canopy Type 1 hood and the appliance surface shall be ____ feet: (A)5' (B)3' (C)6' (D)4' - ANSWER- 4' (IMC 507.4.1) The return air duct to a blower type warm air furnace is being replaced, how many sq. inches of free air are required per 1,000 BTU or rated capacity of the furnace? (A)3" (B)1" (C)4" (D)2" - ANSWER- 2" (Fuel Gas Code 9.3.3.2)

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

HVAC JOURNEYMAN EXAM 2024-2025/TEST EXAM

WITH OVER 300 QUESTIONS AND CORRECT

ELABORATED ANSWERS ALREADY RATED BY

EXPERTS AS THE BEST EXAM (GRADED A+)


A listed smoke damper designed to resist the passage of smoke shall be provided at

each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire

rated wall (C)interior wall (D)corridor wall - ANSWER- Corridor wall (IMC 607.5.4)



Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' - ANSWER- 14' (IMC

603.6.1.1)



The maximum vertical distance between the front lower lip of a canopy Type 1 hood and

the appliance surface shall be ____ feet: (A)5' (B)3' (C)6' (D)4' - ANSWER- 4' (IMC

507.4.1)



The return air duct to a blower type warm air furnace is being replaced, how many sq.

inches of free air are required per 1,000 BTU or rated capacity of the furnace? (A)3"

(B)1" (C)4" (D)2" - ANSWER- 2" (Fuel Gas Code 9.3.3.2)

,The existing terminals of a mechanical draft system shall not be less than ___ feet

above finished ground level where located adjacent to public walkways: (A)7' (B)2' (C)8'

(D)5' - ANSWER- 7' (IMC 804.3.4 #1)



What device is installed to prevent a back draft occurring in an appliance? (A)Power

draft vent (B)Vent cap (C)Saftey relief valve (D)Draft hood - ANSWER- Draft hood (Fuel

Gas Code, 3.3.33)

Minimum distance between the lowest edge of a grease filter and the cooking surface

with exposed flame or burners is: (A)42" (B)6" (C)48" (D)24" - ANSWER- 24" (IMC

Table 507.2.8)



Non-metallic ducts shall have a flame spread index of ___ or less and a smoke-

devolped index of ___ or less: (A)100,200 (B)84,723 (C)50,100 (D)25,50 - ANSWER-

25,50 (IMC 602.2.1)



A blower fan used for the purpose of distributing supply air to a room, space, or area is

a: (A)Air-handling unit (B)Return fan (C)Make-up fan (D)Exhaust fan - ANSWER- Air

handling unit (IMC Chapter #2)



Maximum flame spread distance of ___ feet for combustable electrical wires, cables,

and optical fiber cables exposed within a plenum: (A)30' (B)3' (C)70' (D)5' - ANSWER-

5' (IMC 602.2.1.1)

,Where all combustion air is provided by a mechanical air supply system, the combustion

air shall be supplied from outdoors at the minimum rate of: (A)100ft3/1000BTU/hr

(B)0.35ft3/1000BTU/hr (C) 25ft3/1000BTU/hr (D)50ft/1000BTU/hr - ANSWER-

0.35ft3/1000BTU/hr (Fuel Gas Code, 9.3.6)



A chimney for a residential type or low-heat appliances shall exceed at least ___ feet

above the highest point where it passes through the roof of a building? (A)5' (B)2' (C)10'

(D)3' - ANSWER- 3' (Fuel Gas Code, 12.6.2.1)



A chimney for a low heat appliance must withstand a continuous flue gas temperature

not exceeding ___: (A)1000 (B)1800 (C)800 (D)1200 - ANSWER- 1000 (IMC 202

Appliance Type)



When running flue gas pipe, any angle greater than ___ from the vertical is considered

to be horizontal: (A)30 (B)60 (C)45 (D)90 - ANSWER- 45 (Fuel Gas Code, 12.7.3.2)



A direct vent appliance with an input over 50,000BTU/hr, shall have at least ___ inches

from any air opening into a building: (A)12 (B)6 (C)18 (D)9 - ANSWER- 12 (Fuel code

12.9.3)



Unless otherwise specified by the designer, that sealing requirements do not contain

provisions to: withstanding temperatures higher than ___ degrees F, or lower than ___

, degrees F: (A)120, 40 (B)175, -30 (C)40,120 (D)212, 32 - ANSWER- 120, 40 (SMACNA

S1.9 e. 4. )



What minimum pitch per foot is required for the horizontal run of a vent connector?

(A)3/4" (B)1/4" (C)1" (D)1/2" - ANSWER- 1/4" (Fuel code 12.11.7)



Maximum allowable load size for 1"x18Ga. hanger is: (A)420lbs (B)260lbs (C)700lbs

(D)320LBS - ANSWER- 420lbs (SMACNA Table 5-1)



At least ___ feet of clearance shall be available between the access opening and the

edge of the roof: (A)8' (B)4' (C)10' (D)6' - ANSWER- 6' (Fuel code 9.4.3.3)



A type 1 hood shall have what minimum clearance to combustable materials? (A)14"

(B)6" (C)18" (D)10" - ANSWER- 18" (IMC 507.2.6)



Unless complying as underground duct per section 603.8, ducts shall be installed a

minimum of ___ inches from the earth: (A)4" (B)2" (C)6" (D)3' - ANSWER- 4" (IMC

603.14)



Smoke detectors shall be located downstream of an air filter and ahead of any branch

connectors in a return stream with flow greater than: (A)4,000CFM (B)2,000CFM

(C)5,000CFM (D)3,000CFM - ANSWER- 2,000CFM (IMC 606.2.1)

Geschreven voor

Vak

Documentinformatie

Geüpload op
10 juli 2024
Aantal pagina's
51
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€19,43
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NursingSolutions Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
121
Lid sinds
2 jaar
Aantal volgers
7
Documenten
1753
Laatst verkocht
1 week geleden
CAMILA SOLUTIONS

I am passionate and reliable in my work as a tutor, I offer high-quality Test Banks, Solution manuals, study notes, past exams, and comprehensive learning resources to help students succeed academically. My materials are carefully crafted to cover key concepts, exam patterns, and essential topics, providing a valuable supplement to your studies. . May you Prosper in your field of studies.

3,6

18 beoordelingen

5
9
4
1
3
4
2
0
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen