S-12 CITYWIDE SPRINKLER SYSTEMS EXAM NEWEST
2024 ACTUAL EXAM COMPLETE 250 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |
ALREADY GRADED A
The pressure difference for the clapper valve to open is ___ to ___ psi. - ANSWER: 2
to 5 psi

Maintenance on tanks is every ____ ____. - ANSWER: 3 years

A sprinkler system is a ____ ____ ____ that uses _____ as the extinguishing agent. -
ANSWER: Fire extinguishing system, water

Automatic and nonautimatic sprinkler systems shall be inspected and tested by a
competent person holding a ____ ___ ______. - ANSWER: Certificate of Fitness

A detailed record must be kept of each inspection for examination by any rep of the
____ ____. - ANSWER: Fire Department

A supply of ____ extra sprinkler heads shall be kept available for to replace any fused
or damaged sprinklers. - ANSWER: 6

At least once in____ years, the FD connections must be _______ ______ tested. -
ANSWER: Once in 5 years, hydostatic pressure tested

The hydrostatic pressure test must be conducted by a _____ Fire Suppression _____
______ in the presence of a _____ _____ _______. - ANSWER: Master FireSupression
Piping Contractor, Fire Department representative

There shall be one or more employees with a _____ ___ _____ to inspect the
sprinkler system following the standard of the ______ of ____. - ANSWER: Cof, NFPA
25 of 2002

It shall be the ____'s responsibility to maintain the ___ _____ and to determine the
qualifications of his ____ ____ ______ holder to perform certain functions related to
_____, ____, and _____. - ANSWER: Owner's, sprinkler system, Cof, inspection,
testing, maintenance

901.6.2 says that records of all system inspections, tests, servicing, and other
maintenance must be maintained on the premises for a minimum of ____ years. -
ANSWER: 3 years

901.7.1 says that the owner shall assign an ____ _____ to comply with requirements.
In the absence, the ____ shall be considered the ______ _____. - ANSWER:
Impairment coordinator, owner, ic

, The impairment coordinator shall maintain all ____ of all _____, ____, and _____ for
_____ years. - ANSWER: Records, tests, inspections, maintenance, 3 years

Planned out of service systems for minor repairs or construction affecting not more
than ____ floor, the _____ holder and _____ _____ must be made aware of and
authorize the system out of service. - ANSWER: 1 floor, Cof, impairment coordinator

For an unplanned out of service condition a ____ _____ in the sprinkler system must
occur. - ANSWER: Serious defect

Unplanned or planned shutdown?
Empty tank - ANSWER: Unplanned

Unplanned or planned shutdown?
Testing - ANSWER: Planned

Unplanned or planned shutdown?
Defective fire department connections - ANSWER: Unplanned

For a planned removal of service, ___ _____ to the FDNY is required provided the
system returns to service within an ____ hour period and all the other fire protection
systems are ____ _____. - ANSWER: No notification, 8 hours, fully operational

For an unplanned removal of service, the person responsible for operation must
immediately report the condition to the ____ _____ and to the _____ _____
Borough Communications office. 901.7.5 - ANSWER: Building owner, FD

The initial FD notification shall include 5 things. Name them! - ANSWER: 1)
Description of condition
2)area effected
3) type of emergency
4) time system will be out of service
5) name and phone number of the person making notification

When the Cof holder observes a minor defect, he shall report the condition to the
____ ____ and if it is not corrected within ____ days it shall be deemed an ____ and
reported in _____ to the ____ ____. - ANSWER: Building owner, 30, impairment,
writing, FD

Systems out of service shall be identified by placing a ___ at the fire department
_____, system ____ _____, and the _____ _____ center. - ANSWER: Tag,
connections, control valves, fire command

For an unplanned out of service condition a _____ (____ or ____) shall be placed at
all affected fire department connections. - ANSWER: Disc, white or blue

Gekoppeld boek

Geschreven voor

Vak

Documentinformatie

Geüpload op
18 september 2024
Aantal pagina's
5
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€16,41
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
maxmaxwellmm254 University College Maastricht
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
9
Lid sinds
1 jaar
Aantal volgers
1
Documenten
839
Laatst verkocht
8 maanden geleden
EXCELLENT HOMEWORK

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why i'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Lees meer Lees minder
4,9

135 beoordelingen

5
123
4
11
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen