Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

C-5 APU TEST QUESTIONS AND ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
10-12-2024
Geschreven in
2024/2025

C-5 APU TEST QUESTIONS AND ANSWERS

Instelling
APU
Vak
APU

Voorbeeld van de inhoud

C-5 APU TEST QUESTIONS AND ANSWERS

Do not operate the APU w/ APU compartment door open unless... - Answers - an
external fire guard w/ adequate fire extinguisher is stationed at APU compartment

What is required when operating the APU/ATM sys in hangers NOT EQUIPPED w/
automatic fire suppression system (FSS)? - Answers - Two 150 lbs HALON fire
extinguishers; one near running APU/ATM and a major CRASH/FIRE/RESCUE (CFR)
vehicle must be on stanby outside the hangar.

One hangar door must be open how many feet? and for what reasons? - Answers - 50
Feet, to allow ventilation and if needed CFR vehicle access.

Left and Right APU start accumulatiors must be pressurized to a min of? - Answers -
2,800 PSI (at 0* F and above)

What is the MIN BATT voltage? - Answers - 22.5 VDC

What is the result of having an UN-serviceable battery installed and connected? -
Answers - Total deactivation of the fire fighting capabilities at the nose wheel well FSS
control panel.

How much fuel is needed and in which tanks for operating APU/ATM systems. Explain
why. - Answers - 4,500 lbs min in MAIN Tanks 2 and 3 for Hyd system operation plus
APU operating fuel. BONUS* Why HYD?

When will the audible warning horn be inoperative? - Answers - If the #1 touchdown
relay c/b is open or if the airplane is on jacks

At what time is it ok for a ground observer to attempt to fight a fire and through what
door? - Answers - Not until the APU start has been terminated and through the APU
push-in door

If there is no external power available for an APU start, what must be accompished? -
Answers - A fire truck must be standing by

If the APU is started without external power, what indication(s) will you not have? -
Answers - No fire detection or EGT indication

If during start the EGT indication of 715*C or elapsed time of 30 sec(0*C and above)
from start to ON SPEED lights illuminate is exceeded, what should be done? - Answers
- Terminate start immediately and do not attempt to restart until the malfunction has
been corrected

What are the APU operation limits? - Answers - 1) 0*C to 715*C starting normal

, 2) 715*C to 824*C for 20 seconds max transient limit during start
3) 691*C to 746*C 3 minutes max upon applying load at governed speed
4) 600*C to 691*C full load continous

What do you do if either batt is below the min voltage? - Answers - Replace batt if
available, if not available open batt C/B or disconnect connector to avoid damage to batt
when pwr is applied.

What is the range the DC volts meter shall indicate? - Answers - 25-30 VDC

During APU start up and operation what position must the battery switch be in and why?
- Answers - BATT switch must be in the ON position for fire handle shutdown and fire
extinguisher discharge.

The UHF/VHF radios will be set to the fequency that communicates with whom? -
Answers - Ground control/ control tower frequency

What is the FREQ meter on the AC SYS CONTROL PANEL supposed to indicate? -
Answers - 394 to 406 (400 +/- 6)

What is the AC volt meter on the AC SYS CONTROL PANEL supposed to indicate? -
Answers - 112 to 118 VAC (115 +/- 3)

What is the AC load meter on the AC SYS CONTROL PANEL supposed to indicate? -
Answers - 1.0

How many seconds do you leave the APU/OFF/EXT PWR switch to off before placing to
APU? - Answers - 2 Seconds

How long should you allow the APU to warm up before applying an air load? - Answers -
2 minutes

When starting ATM/PTU why should you check with the ground observer the position of
the flaps/slats in reference to the Flap handle? - Answers - Application of HYD power
will cause surfaces to move to position commanded by the handle setting.

When can you shut off the Electric Suction Boost pumps while opperating Hyd
Systems? - Answers - Never

Where must personnel be stationed when operating ATM's? - Answers - A qualified
operator must be at the FE station to monitor ATM operation.

During the start of an ATM what is the time limit for hydraulic pressure to reach
operating range? - Answers - 15 seconds

Geschreven voor

Instelling
APU
Vak
APU

Documentinformatie

Geüpload op
10 december 2024
Aantal pagina's
5
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,26
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
GEEKA YALA UNIVERSITY
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2109
Lid sinds
4 jaar
Aantal volgers
1446
Documenten
54250
Laatst verkocht
4 dagen geleden

3,8

358 beoordelingen

5
177
4
61
3
48
2
17
1
55

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen