1. The SI unit of length is the Meter

2. The Pascal, the SI unit of pressure, is A derived SI unit

3. Which SI multipliers have abbreviations in capital Those with factors
letters? > 1000

4. The speed of light is considered to be a constant When used for
standards work

5. The melting point of Gallium is a fixed point in the Zero
ITS-90 temperature system. The uncertainty of the
value of this temperature is

6. A certificate for a traceable calibration must show The existence of a
evidence to support traceability path is
needed for an au-
dit

7. The realization of a temperature fixed point is A physical object
such as a freezing
point cell

8. Traceability is required when operating under ISO At every step
9001 and related standards of the calibra-
tion pyramid below
national measure-
ment standards

9. The ACME company's calibration procedure for their Stop work and no-
model VU-1 sound level meter calls for the exclusive tify the customer
use of ACME sound level calibrator model SLC-1. A that the calibration
technician has a rush job to calibrate a VU-1, but the cannot be com-
SLC-1 is back at the factory in Europe for repair and pleted until the
calibration. He/she should proper IM&TE is
available

10. In order to calibrate a digital ammeter, it is necessary A source or gener-
to have ator of current



, ASQ Calibration Technician Certification Latest 2024 -2025

11. The base SI unit for electrical quantities is Ampere

12. One gram of oxygen gas is released into a box 10 cm 1.0 kg/m^3
on a side. What is the SI density of the gas inside the
box when equilibrium is reached?

13. One million nanofarads is the same as One millifarad

14. Scales and balances should be calibrated after they Gravity is different
are moved because in different places
and internal mech-
anisms may have
been affected

15. A triple point of water cell is A device for sourc-
ing temperature

16. Substitution of standards May be done if
technically feasi-
ble and not forbid-
den by procedure

17. Which of the following measuring systems is a resis- Thermistor
tance-temperature device (RTD)?

18. Having traceable reference standards and providing These customers
traceable calibrations for a laboratory's customers is need to provide
necessary when traceability to their
customers

19. An optical pyrometer measures temperature by deter- The color of the
mining light from a hot
body

20. An intrinsic standard Will realize the unit
for which it is a ref-
erence when op-
erated properly

21. Temperature


, ASQ Calibration Technician Certification Latest 2024 -2025

The largest single contributor to the uncertainty of
dimensional measurements is

22. The SI unit for time is based on An atomic vibra-
tion

23. Which of the following notations accepted for use 3.785 L (1 U.S.
with the SI is preferred for the volume of a gallon of gallon)
milk?

24. Carl Sagan, on his television series, might have said Half an hour
"Thank you for spending these billions and billions
of nanoseconds with me." How long a time interval
is 1800 billion ns? Note - use the U.S. definition of
billion, e.g. 10^9

25. Gravitational corrections are always required for Measurements in
which a weight
opposes a spring
force

26. Which of the following temperature measuring de- Thermocouple
vices requires either an actual or a simulated refer-
ence temperature?

27. Crash dummies used to simulate the effects of adults Consensus stan-
and children during testing of car and truck collisions dard
are an example of a

28. Electrical sensors used to measure temperature al- Linearization of
most always require the temperature -
electrical relation-
ship

29. A substitute standard has replaced the usual refer- The substitute
ence standard and the term "limited calibration" is was used for a lim-
used on the UUT. Which of the following explanations ited time
would NOT be expected as an explanation of the lim-
ited calibration?

Documentinformatie

Geüpload op
31 december 2024
Aantal pagina's
23
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€13,16
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
TestPrepPros

Maak kennis met de verkoper

Seller avatar
TestPrepPros Universiteit van Amsterdam
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
1 jaar
Aantal volgers
0
Documenten
79
Laatst verkocht
-

BUY WITHOUT DOUBT AND PASS YOUR EXAMS WITH EXCELLENT GRADES!!!

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen