This document provides a complete review for the Commercial Refrigeration Certification exam, covering refrigeration cycle fundamentals, system components, diagnostics, and maintenance procedures. It also includes content on EPA regulations, refrigerant handling, and safety protocols. Ideal for HVAC technicians and trainees preparing for certification in commercial refrigeration.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Commercial Refrigeration Certification
In a dry type (direct expansion) evaporator, liquid refrigerant must boil away as close to
the end of the coil as possible in order to:
A. operate at high efficiency.
B. ensure that frost does not accumulate.
C. sub-cool the compressor.
D. ensure proper oil return. - *answers *A. operate at high efficiency.

The difference between the temperature of the refrigerant boiling in the evaporator and
the temperature at the evaporator outlet is known as:
A. evaporator superheat.
B. latent heat.
C. evaporator sub-cooling.
D. sublimation. - *answers *A. evaporator superheat.

An expansion device that is stuck open will cause:
A. low suction pressure
B. a starved evaporator.
C. excessive superheat
D. a flooded evaporator - *answers *D. a flooded evaporator

When measuring evaporator superheat on a commercial system that has a long suction
line, the pressure reading should be taken at the:
A. compressor inlet.
B. evaporator outlet.
C. condenser outlet.
D. receiver Inlet. - *answers *A. compressor inlet. (Suction Line)

Superheat measurements are best taken:
A. during a hot pull down.
B. at 8°F to 12°F.
C. during defrost.
D. with the system operating at design conditions. - *answers *D. with the system
operating at design conditions.

A technician is checking the superheat on a multi circuit evaporator and finds one of the
circuits has a superheat that is higher than the others. This could be caused by:
A. a dirty coil.
B. a refrigerant overcharge
C. uneven air distribution.
D. a blocked distributor. - *answers *D. a blocked distributor.

A TEV with an external equalizer is used on:
A. evaporators with a high pressure drop.
B. evaporators with a low pressure drop.
C. high temperature applications only.
D. all evaporators. - *answers *A. evaporators with a high pressure drop.

,Commercial Refrigeration Certification
Dry type evaporators operate most efficiently with a superheat setting of approximately:
A. 8° F to 12°F
B. 13° F to 19°F
C. 20° F to 30°F
D. 31° F to 40° F - *answers *A. 8° F to 12°F

An evaporator used to chill liquids in operating with a normal superheat setting, but the
system is not cooling the product properly. Which of the following is the most likely
cause?
A. overcharge of refrigerant
B. undercharge of refrigerant
C. the circulator
D. the TEV - *answers *C. the circulator

What time interval is required between each superheat adjustment?
A. Not less than 1 hour
B. About 10-15 minutes
C. At least 1/2 hour.
D. No time delay. - *answers *B. About 10-15 minutes

A low temperature evaporator used for cooling space or product refrigeration:
A. is the same as one used for medium or high temperatures.
B. must have fins spaced closer together.
C. must be frosted periodically.
D. must be defrosted periodically. - *answers *D. must be defrosted periodically.

Some special applications use a flooded evaporator (operated full of refrigerant). In
order to maintain the proper level of liquid refrigerant, a ____ type metering device is
used.
A. TEV
B. capillary tube
C. AEV
D. float - *answers *D. float

A properly functioning condenser will first:
A. condense then de-superheat.
B. subcool then de-superheat.
C. subcool then superheat.
D. de-superheat then subcool. - *answers *D. de-superheat then subcool.

Tube within a tube, shell and coil, and shell and tube are all types of:
A. water cooled condensers.
B. air cooled condensers.
C. receivers.
D. accumulators. - *answers *A. water cooled condensers.

, Commercial Refrigeration Certification
The refrigerant condensing temperature in a water cooled condenser is normally about
____ higher than the leaving water.
A. 100°F
B. 10°F
C. 30°F
D. 75°F - *answers *B. 10°F

The refrigerant in an air cooled condenser will normally condense at approximately
_____ higher temperature than the air passing over it.
A. 10°F
B. 30°F
C. 75°F
D. 100°F - *answers *B. 30°F

Workable head pressure during periods of low ambient temperature can be achieved by
using:
A. an economizer
B. evaporator dampers
C. evaporator flooding
D. fan-cycle control - *answers *D. fan-cycle control

Cooling towers that pass air over water to remove system heat are limited in capacity
by:
A. outside air wet bulb temperature.
B. outside air dry bulb temperature
C. inside air wet bulb temperature.
D. inside air dry bulb temperature. - *answers *A. outside air wet bulb temperature.

One of the main reasons that reciprocating compressors are not 100% efficient is:
A. CFC refrigerants.
B. clearance volume.
C. evaporator design
D. condenser design. - *answers *B. clearance volume.

An open drive compressor is most likely to develop a refrigerant leak at the:
A. valve plate.
B. suction service valve.
C. discharge service valve.
D. shaft seal. - *answers *D. shaft seal.

Multiple compressors provide:
A. positive on return.
B. lower humidity in high humidity locales.
C. capacity control
D. zone control. - *answers *C. capacity control

Geschreven voor

Vak

Documentinformatie

Geüpload op
13 januari 2025
Aantal pagina's
16
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,19
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
lizishiru

Maak kennis met de verkoper

Seller avatar
lizishiru University of Nairobi
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
1 jaar
Aantal volgers
0
Documenten
355
Laatst verkocht
-
High-Quality Summaries and Exam Prep

Welcome to my Stuvia profile! I provide high-quality, well-structured academic materials that are designed to support serious learners in achieving their academic goals. My resources include detailed notes, comprehensive summaries, exam preparations, and study guides that are clear, accurate, and aligned with course objectives. Each document is carefully written to ensure clarity, depth, and reliability—making it easier for you to grasp complex concepts, revise efficiently, and excel in your assessments. By choosing my materials, you can expect: ✅ Accurate and well-researched content ✅ Organized and easy-to-follow structure ✅ Reliable support for exams, assignments, and study sessions My goal is to help students save time, study effectively, and achieve outstanding results.

Lees meer Lees minder
0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen