Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

CHEM 123 - Lab final - UBC EXAM 2025 QUESTIONS WITH 100% VERIFIED SOLUTIONS, SCORED A+

Beoordeling
-
Verkocht
1
Pagina's
10
Cijfer
A+
Geüpload op
11-04-2025
Geschreven in
2024/2025

CHEM 123 - Lab final - UBC EXAM 2025 QUESTIONS WITH 100% VERIFIED SOLUTIONS, SCORED A+ /. why do we perform iodometric titrations - Answer-to find the concentration of an unknown by mixing it with a solution of known concentration /.What are the 4 (general) steps of an iodometric titration? - Answer-combine solutions, reach endpoint, calculate, determine the concentration of the unknown /.What reaction takes place during an iodometric titration? - Answer-oxidation-reduction reaction /.what is used as the oxidizing agent in an iodometric titration? - Answer-potassium iodate /.top-loading balance - Answer-- used for prepwork and obtains a mass to the nearest +/-0.1g (uncertainty of +/- 0.05g) - used prior to analytical balance /.analytical balance - Answer-- used to determine a precise mass to the nearest +/- 0.0001 g - masses are always reported to 4 decimal places /.does an analytical balance or top-loading balance need to be recorded to 4 decimal places? - Answer-analytical balance /.when is a reading considered stable? - Answer-if it persists for 2 seconds /.what temperature should objects be weighed? - Answer-at room temperature /.should objects be dry or wet when weighed? - Answer-Dry /.should you use the same balance for all measurements? - Answer-yes /.Describe the steps for weighing by difference - Answer-- place clean empty weigh boat on top loading balance - tare top loading balance & weigh boat to 0.00g - add approximate mass (+/- 20%) of chemical to weigh boat - close all doors on analytical balance and tare it to 0.0000g - weigh the sample & weigh boat and record the value (1) - transfer weighed sample into beaker (from weigh boat) - weigh the emptied weigh boat and record the value (2) Subtract value 2 from value 1 to get the mass of the chemical /.how do we know if something is a standard solution? - Answer-if it has a known concentration to at least 4 significant figures) /.describe the steps to take when preparing a standard solution (in a volumetric flask) - Answer-- weigh & dissolve the solid compound (using weigh by difference) - clean the volumetric flask, funnel, and stopper 3x with deionized water - quantitatively transfer the dissolved sample into the volumetric flask (using and funnel and rinsing beaker/stir rod with deionized water) - fill volumetric flask to a few centimetres below the calibration mark (do not go above this line) - use a dropper to add water dropwise to volumetric flask until the bottom of the meniscus is resting on the calibration line (if you go past calibration mark, you must start over) - stopper the flask and invert the flask 20x /.what is a parallax error? - Answer-when your eye level is higher or lower than the bottom of the meniscus where you must record a volume /.how do you prepare a volumetric pipette? - Answer-clean with deionized water and then rinse with solution that will be pipetted (the sample) /.how to clean a pipette - Answer-- pour at least 25ml of deionized water into a clean beaker - use pipet bulb to half-fill the pipette with deionized water - hold pipette horizontally and role around to coat the inside with water - discharge the water through the tip into the sink or waste beaker - repeat the wash 2 times with deionized water - transfer 25 mL of the solution to be pipetted into a clean & dry beaker - draw approximately 5 mL of solution into the pipet and hold in horizontal position and coat inside with solution - discharge liquid into the sink/waste beaker /.How do you fill a volumetric pipette? - Answer-- hold the pipette near the very top (blunt end) with one hand and the bulb with the other) & make sure the tip is submerged below the surface of the solution & bulb is not yet on the pipette - completely squeeze all air out of pipette bulb & gently put tip of bulb into top of the pipette (never pipette by mouth) - slowly release pressure on the pipette bulb to allow the solution to rise into the pipette (fill to at least 2 cm above calibration line, keep pipette tip in solution to avoid bubbles from entering pipette) - remove the bulb quickly and cover the top of pipette with index-finger of the hand holding the pipette (not with thumb)

Meer zien Lees minder
Instelling
CHEM 123 -
Vak
CHEM 123 -

Voorbeeld van de inhoud

CHEM 123 - Lab final - UBC EXAM 2025 QUESTIONS
WITH 100% VERIFIED SOLUTIONS, SCORED A+

/. why do we perform iodometric titrations - Answer-to find the concentration of an
unknown by mixing it with a solution of known concentration

/.What are the 4 (general) steps of an iodometric titration? - Answer-combine solutions,
reach endpoint, calculate, determine the concentration of the unknown

/.What reaction takes place during an iodometric titration? - Answer-oxidation-reduction
reaction

/.what is used as the oxidizing agent in an iodometric titration? - Answer-potassium
iodate

/.top-loading balance - Answer-- used for prepwork and obtains a mass to the nearest
+/-0.1g (uncertainty of +/- 0.05g)
- used prior to analytical balance

/.analytical balance - Answer-- used to determine a precise mass to the nearest +/-
0.0001 g
- masses are always reported to 4 decimal places

/.does an analytical balance or top-loading balance need to be recorded to 4 decimal
places? - Answer-analytical balance

/.when is a reading considered stable? - Answer-if it persists for 2 seconds

/.what temperature should objects be weighed? - Answer-at room temperature

/.should objects be dry or wet when weighed? - Answer-Dry

/.should you use the same balance for all measurements? - Answer-yes

/.Describe the steps for weighing by difference - Answer-- place clean empty weigh boat
on top loading balance
- tare top loading balance & weigh boat to 0.00g
- add approximate mass (+/- 20%) of chemical to weigh boat
- close all doors on analytical balance and tare it to 0.0000g
- weigh the sample & weigh boat and record the value (1)
- transfer weighed sample into beaker (from weigh boat)
- weigh the emptied weigh boat and record the value (2)

, Subtract value 2 from value 1 to get the mass of the chemical

/.how do we know if something is a standard solution? - Answer-if it has a known
concentration to at least 4 significant figures)

/.describe the steps to take when preparing a standard solution (in a volumetric flask) -
Answer-- weigh & dissolve the solid compound (using weigh by difference)
- clean the volumetric flask, funnel, and stopper 3x with deionized water
- quantitatively transfer the dissolved sample into the volumetric flask (using and funnel
and rinsing beaker/stir rod with deionized water)
- fill volumetric flask to a few centimetres below the calibration mark (do not go above
this line)
- use a dropper to add water dropwise to volumetric flask until the bottom of the
meniscus is resting on the calibration line (if you go past calibration mark, you must start
over)
- stopper the flask and invert the flask 20x

/.what is a parallax error? - Answer-when your eye level is higher or lower than the
bottom of the meniscus where you must record a volume

/.how do you prepare a volumetric pipette? - Answer-clean with deionized water and
then rinse with solution that will be pipetted (the sample)

/.how to clean a pipette - Answer-- pour at least 25ml of deionized water into a clean
beaker
- use pipet bulb to half-fill the pipette with deionized water
- hold pipette horizontally and role around to coat the inside with water
- discharge the water through the tip into the sink or waste beaker
- repeat the wash 2 times with deionized water
- transfer 25 mL of the solution to be pipetted into a clean & dry beaker
- draw approximately 5 mL of solution into the pipet and hold in horizontal position and
coat inside with solution
- discharge liquid into the sink/waste beaker

/.How do you fill a volumetric pipette? - Answer-- hold the pipette near the very top
(blunt end) with one hand and the bulb with the other) & make sure the tip is submerged
below the surface of the solution & bulb is not yet on the pipette
- completely squeeze all air out of pipette bulb & gently put tip of bulb into top of the
pipette (never pipette by mouth)
- slowly release pressure on the pipette bulb to allow the solution to rise into the pipette
(fill to at least 2 cm above calibration line, keep pipette tip in solution to avoid bubbles
from entering pipette)
- remove the bulb quickly and cover the top of pipette with index-finger of the hand
holding the pipette (not with thumb)
- drain solution down to calibration (slowly move index finger covering the top of the
pipette to drain solution to get meniscus resting on the calibration line)

Geschreven voor

Instelling
CHEM 123 -
Vak
CHEM 123 -

Documentinformatie

Geüpload op
11 april 2025
Aantal pagina's
10
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,19
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
kartelodoc Harvard University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
143
Lid sinds
1 jaar
Aantal volgers
7
Documenten
8355
Laatst verkocht
3 weken geleden

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. I WISH YOU SUCCESS IN YOUR EDUCATION JOURNEY

Lees meer Lees minder
3,3

25 beoordelingen

5
8
4
2
3
8
2
3
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen