Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

DC BOILER STATIONARY THIRD TESTING EXAM ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES|AGRADE

Beoordeling
-
Verkocht
1
Pagina's
39
Cijfer
A+
Geüpload op
22-04-2025
Geschreven in
2024/2025

DC BOILER STATIONARY THIRD TESTING EXAM ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES|AGRADE

Instelling
DC BOILER STATIONARY THIRD TESTING
Vak
DC BOILER STATIONARY THIRD TESTING

Voorbeeld van de inhoud

1|Page



DC BOILER STATIONARY THIRD
TESTING EXAM 2025-2026 ACTUAL
EXAM 200 QUESTIONS AND CORRECT
DETAILED ANSWERS WITH
RATIONALES|AGRADE
The component in which liquid vapor by absorbing heat is called? -
(answers)Evaporator



Select the best answer electrical grounding method? - (answers)Metal stake drive
8 foot into the ground.



A _____ valve should be used for throttling purpose? - (answers)Globe



What is the acceptable range for residual sodium sulfite in the boiler maintain? -
(answers)30-70



What is the BTU content of a gallon of #4? - (answers)146,000



What does a zeolite water softener system use as a means of regeneration? -
(answers)Brine



What are the 4 steps for a Zeolite Rejuvenation water softener process? -
(answers)Back wash

Backwash, brine, rinse, service

,2|Page




Where is medium temperature is liquid found? - (answers)Condenser



Where is high temperature vapor found? - (answers)At the discharge of the
compressor or condenser



What stays are used to support the burner chamber in a scotch marine boiler? -
(answers)Diagonal Stays



What type of safety valve is this? - (answers)( Full) Crosby nozzle-type safety
valve. Page 365 BOG



What type of safety valve is this? - (answers)( Full) Crosby nozzle-type safety
valve. Page 365 BOG



Where do you found superheat reading? - (answers)Take suction line pressure

Cross reference using a P/T Chart

Get tail coil Temperature

Subtract cross references temperature from tail coil temperature

Result will be superheat



Name the wire that connects all component of a system to a physical ground or
water pipe? - (answers)Grounding Electrode Conductor

,3|Page




Where do get sub-cooling reading? - (answers)Take liquid line pressure

Cross reference to temperature using a P/T Chart

Get liquid line temperature

Subtract actual temperature from cross referenced temperature

Result is sub-cooling



On the boilers that have both Quick opening and Screw type blow down valves,
the Quick opening valve must be located? - (answers)Closest to the boiler and
followed by the screw type valve



High pressure boilers equipped with Quick opening and Screw type valves are
blown down how? - (answers)By opening the Quick opening valve first and closing
it Last. Page 403 BOG



ASME Code defines a slow opening valve as what? - (answers)One requiring at
least 5 full 360 degree turns between full open and close position. Page 374



A 300 Horsepower boiler operating at 100psi has an average load of 75% with
80% condensate return and 5% blow down. The treatment provides a chemical
which costs $8.75 per gallon, and will treat 600 gallon. Find the amount of the
chemical needed for the day period, and the cost of the chemical for a 30 days
period? - (answers)Water In = Water Out

Makeup + Condensate Return = Evaporator + Blow Down

, 4|Page


Average Evaporator Rate = 300 x 34.5 pph x .75% load = 7762, 50 pph



1 Month + .8( 7762.50 pph) = 7762.50 pph + 0500 m



1 Month + 6210 pph = 7762.50 pph + .0500 m

-6210 -6210

1 Month = 1552.5 pph + .0500



.9500 m = 1552.5 pph

.9500m .9500



1Month = 1,634.21 pph



Gallons per Month = 1634..33 x 24 x 30 = 141, 252.24 gallons per month

Chemical needed = 141,252.24 gallon / 600 gallon = 235, 40 gallon



Cost per month = 235, 40 gallon x 8.75 = $2,059.75



During a 24 hours operation how often should you check the water level? -
(answers)Once per shift



A 15 psi steam boiler produces 8000 pound of steam per hour. The

Geschreven voor

Instelling
DC BOILER STATIONARY THIRD TESTING
Vak
DC BOILER STATIONARY THIRD TESTING

Documentinformatie

Geüpload op
22 april 2025
Aantal pagina's
39
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Gratis
Krijg toegang tot het volledige document:
Downloaden

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
DocBeast Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
10753
Lid sinds
1 jaar
Aantal volgers
7
Documenten
2768
Laatst verkocht
2 dagen geleden

4,9

626 beoordelingen

5
602
4
17
3
5
2
1
1
1

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen