Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

S-95 SUPERVISION OF FIRE ALARM SYSTEMS QUESTIONS WITH CORRECT COMPLETE SOLUTIONS

Beoordeling
-
Verkocht
-
Pagina's
6
Cijfer
A+
Geüpload op
02-07-2025
Geschreven in
2024/2025

____________ detectors contain multiple sensors and are capable of generating multiple alarms. - multi-sensor ____________ detectors employ more than one operating principle and operate independent of each other. - combination ____________ detectors are used to protect large areas. it is a light beam broken by combustible particles. - beam ___________ detectors shut down a buildings hvac system and redirect airflow. - dust smoke fire alarm devices shall be protected, especially during ___________. - installation for air sampling type detectors, the maximum air sampling transport time from the farthes point shall not exceed ____________. - 120 seconds air-sampling detectors shall give a ____________ signal if the airflow is outside the manufacurers specified range. - trouble maximum allowable time for fire alarm output functions to operate once a smoke detector has been activated is __________ seconds. - 10 __________ heat detectors do not have to be replaced after it has activated the fire alarm. - rate of rise

Meer zien Lees minder
Instelling
S-95 SUPERVISION OF FIRE ALARM
Vak
S-95 SUPERVISION OF FIRE ALARM

Voorbeeld van de inhoud

S-95 SUPERVISION OF FIRE ALARM
SYSTEMS

____________ detectors contain multiple sensors and are capable of
generating multiple alarms. - ✔ ✔ multi-sensor

____________ detectors employ more than one operating principle
and operate independent of each other. - ✔ ✔ combination

____________ detectors are used to protect large areas. it is a light
beam broken by combustible particles. - ✔ ✔ beam

___________ detectors shut down a buildings hvac system and re-
direct airflow. - ✔ ✔ dust smoke

fire alarm devices shall be protected, especially during ___________. -
✔ ✔ installation

for air sampling type detectors, the maximum air sampling transport
time from the farthes point shall not exceed ____________. - ✔ ✔
120 seconds

air-sampling detectors shall give a ____________ signal if the airflow is
outside the manufacurers specified range. - ✔ ✔ trouble

maximum allowable time for fire alarm output functions to operate
once a smoke detector has been activated is __________ seconds. - ✔
✔ 10

__________ heat detectors do not have to be replaced after it has
activated the fire alarm. - ✔ ✔ rate of rise

, ________ heat detectors activate the alarm when the detector
components melt at a preset temperature. - ✔ ✔ fixed-temperature
heat detectors

__________ heat detectors are the most commonly used. - ✔ ✔
fixed-temperature

___________ detectors are required in any building that has fossil fuel
burning equipment. - ✔ ✔ carbon monoxide

the _________ shall only be reset at the direction of a fire department
representative. - ✔ ✔ fire alarm control panel

single action stations are usually found __________. - ✔ ✔ indoors

once activated, the fire alarm system cannot be re-set at the
_____________. - ✔ ✔ fire alarm manual pull station

a master plumber with an s-12 cof is allowed to perform maintenance
on sprinkler systems in residential occupancies with less than
____________ sprinklers. - ✔ ✔ 30

when a ____________ condition is indicated, the cof holder should
check the system in order to identify the part of the system that caused
the signal. - ✔ ✔ supervisory

all subsystems are subject to fdny inspection and test for issuance of
_______________. - ✔ ✔ letter of approval

in large buildings, the fire annunciator may be associated with
____________ control and _____________ systems. - ✔ ✔ smoke
purge, communications

Geschreven voor

Instelling
S-95 SUPERVISION OF FIRE ALARM
Vak
S-95 SUPERVISION OF FIRE ALARM

Documentinformatie

Geüpload op
2 juli 2025
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€7,94
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
jackline98 Stanford University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
269
Lid sinds
2 jaar
Aantal volgers
152
Documenten
9860
Laatst verkocht
2 weken geleden

Here you will find different past papers with correct and updated solutions .Please do not forget to leave a review after purchasing any document .Goodluck and success in advance.

3,3

61 beoordelingen

5
21
4
11
3
9
2
5
1
15

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen