STATIONARY ENGINEER BOILER EXAM LATEST VERSIONS 2024 (VERSION A AND B) ACTUAL EXAM
COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS
Pressure gauges should never have a range less than
A. half the safety valve set pressure.
B. double the safety valve set pressure.
C. 3/4 times the safety valve set pressure.
D. 1 1/2 times the safety valve set pressure. - (answer) D. 1 1/2 times the safety valve set pressure.
After water is blown out of a siphon, why should live steam never be allowed to enter a Bourdon tube?
A. The steam will rupture the siphon tube.
B. Combustion gases will mix with the steam.
C. Live steam will damage the pressure gauge.
D. The water level gauge will be damaged or destroyed. - (answer) C. Live steam will damage the
pressure gauge.
All of the following are essential to maintain the proper fuel oil pressure with fuel oil accessories EXCEPT
A. achieving the right flow of fuel.
B. proper atomization of the fuel oil.
C. heating fuel oil to the correct temperature.
D. obtaining the correct difference in pressure inside and outside the boiler. - (answer) D. obtaining the
correct difference in pressure inside and outside the boiler.
Which of the following could be dangerous to safe operation of a low pressure boiler?
A. Adding water to an operating boiler when the water level cannot be seen in the gauge glass tube.
B. Opening the blowdown valve at the bottom of the water gauge glass before making a water level
reading.
C. Checking the water level using the try cocks valves when the line to the glass gauge tube is clogged.
D. Opening the water column blowdown valve every day. - (answer) A. Adding water to an operating
boiler when the water level cannot be seen in the gauge glass tube.
Which of the following is best if a low-pressure boiler does not have an air vent?
,STATIONARY ENGINEER BOILER EXAM LATEST VERSIONS 2024 (VERSION A AND B) ACTUAL EXAM
COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS
A. Vent the boiler with the try cocks.
B. Vent the boiler with the safety valve.
C. Vent the boiler with the fusible plug.
D. Vent the boiler with the blowdown line. - (answer) A. Vent the boiler with the try cocks.
What is the purpose of an evaporation test on a low pressure boiler?
A. To test the water column
B. To test the bottom blowdown valve
C. To test the steam pressure safety valve
D. To test the low water cutoff control. - (answer) D. To test the low water cutoff control.
Following flame failure, controls must de-energize fuel and ignition circuits
A. within 4 seconds.
B. within 6 seconds.
C. within 10 seconds.
D. within 15 seconds. - (answer) A. within 4 seconds.
How can an operator prevent damage to the tubes while using a cleaner to remove scale from boiler
tubes?
A. Never use a chemical cleaning procedure.
B. Never use cleaning water under pressure.
C. Never allow the cleaner to stay in one place.
D. Never clean the tubes more often than every six months. - (answer) C. Never allow the cleaner to
stay in one place.
In a steam boiler, which of the following should never be placed between the safety relief valve and the
boiler?
A. A steam trap
B. A shut-off valve
, STATIONARY ENGINEER BOILER EXAM LATEST VERSIONS 2024 (VERSION A AND B) ACTUAL EXAM
COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS
C. An air eliminator
D. A discharge pipe - (answer) B. A shut-off valve
Which of these should be used on live electrical fires?
A. Class D extinguishers
B. Class C extinguishers
C. Class B extinguishers
D. Class A extinguishers - (answer) B. Class C extinguishers
If certain grades of fuel oil are not preheated properly, they may cause
A. higher temperatures in the furnace.
B. back pressure and leaks in the fuel lines.
C. poor combustion and high fuel consumption.
D. increased pressure and dangerous levels of steam. - (answer) C. poor combustion and high fuel
consumption.
The furnace is almost always in a ___________ pressure.
Negative
Positive - (answer) Negative
In an open feedwater heater or de-aerating feedwater tank, a clogged vent line will _______ air/non-
condensables in feedwater.
Increase
Decrease - (answer) Increase
COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS
Pressure gauges should never have a range less than
A. half the safety valve set pressure.
B. double the safety valve set pressure.
C. 3/4 times the safety valve set pressure.
D. 1 1/2 times the safety valve set pressure. - (answer) D. 1 1/2 times the safety valve set pressure.
After water is blown out of a siphon, why should live steam never be allowed to enter a Bourdon tube?
A. The steam will rupture the siphon tube.
B. Combustion gases will mix with the steam.
C. Live steam will damage the pressure gauge.
D. The water level gauge will be damaged or destroyed. - (answer) C. Live steam will damage the
pressure gauge.
All of the following are essential to maintain the proper fuel oil pressure with fuel oil accessories EXCEPT
A. achieving the right flow of fuel.
B. proper atomization of the fuel oil.
C. heating fuel oil to the correct temperature.
D. obtaining the correct difference in pressure inside and outside the boiler. - (answer) D. obtaining the
correct difference in pressure inside and outside the boiler.
Which of the following could be dangerous to safe operation of a low pressure boiler?
A. Adding water to an operating boiler when the water level cannot be seen in the gauge glass tube.
B. Opening the blowdown valve at the bottom of the water gauge glass before making a water level
reading.
C. Checking the water level using the try cocks valves when the line to the glass gauge tube is clogged.
D. Opening the water column blowdown valve every day. - (answer) A. Adding water to an operating
boiler when the water level cannot be seen in the gauge glass tube.
Which of the following is best if a low-pressure boiler does not have an air vent?
,STATIONARY ENGINEER BOILER EXAM LATEST VERSIONS 2024 (VERSION A AND B) ACTUAL EXAM
COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS
A. Vent the boiler with the try cocks.
B. Vent the boiler with the safety valve.
C. Vent the boiler with the fusible plug.
D. Vent the boiler with the blowdown line. - (answer) A. Vent the boiler with the try cocks.
What is the purpose of an evaporation test on a low pressure boiler?
A. To test the water column
B. To test the bottom blowdown valve
C. To test the steam pressure safety valve
D. To test the low water cutoff control. - (answer) D. To test the low water cutoff control.
Following flame failure, controls must de-energize fuel and ignition circuits
A. within 4 seconds.
B. within 6 seconds.
C. within 10 seconds.
D. within 15 seconds. - (answer) A. within 4 seconds.
How can an operator prevent damage to the tubes while using a cleaner to remove scale from boiler
tubes?
A. Never use a chemical cleaning procedure.
B. Never use cleaning water under pressure.
C. Never allow the cleaner to stay in one place.
D. Never clean the tubes more often than every six months. - (answer) C. Never allow the cleaner to
stay in one place.
In a steam boiler, which of the following should never be placed between the safety relief valve and the
boiler?
A. A steam trap
B. A shut-off valve
, STATIONARY ENGINEER BOILER EXAM LATEST VERSIONS 2024 (VERSION A AND B) ACTUAL EXAM
COMPLETE 200 QUESTIONS AND CORRECT DETAILED ANSWERS
C. An air eliminator
D. A discharge pipe - (answer) B. A shut-off valve
Which of these should be used on live electrical fires?
A. Class D extinguishers
B. Class C extinguishers
C. Class B extinguishers
D. Class A extinguishers - (answer) B. Class C extinguishers
If certain grades of fuel oil are not preheated properly, they may cause
A. higher temperatures in the furnace.
B. back pressure and leaks in the fuel lines.
C. poor combustion and high fuel consumption.
D. increased pressure and dangerous levels of steam. - (answer) C. poor combustion and high fuel
consumption.
The furnace is almost always in a ___________ pressure.
Negative
Positive - (answer) Negative
In an open feedwater heater or de-aerating feedwater tank, a clogged vent line will _______ air/non-
condensables in feedwater.
Increase