Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

California UST Service Technician part 1

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
20-08-2025
Geschreven in
2025/2026

California UST Service Technician part 1

Instelling
California UST
Vak
California UST

Voorbeeld van de inhoud

California UST Service Technician part
1exam with complete solutions
July 1 2005, service techs shall possess or work under someone who has a current
certification indicating he or she has passed the ? -ANSCalifornia UST service
technician exam

ICC cert must be renewed every? -ANS24 months

Service techs must posses or be employed by a person who has the appropriate
contractors license unless? -ANSThe individual has a Tank testing licens

Service tech is defined by any individual who? -ANSTest UST monitoring equipment
Trouble shoots UST systems
Installs UST monitoring equipment

If the manufacturer training no longer exist , the local angency may? -ANSApprove
comparable alternat training .

UST includes? -ANSTank and connected piping

What is considered and UST -ANSpetroleum storage tank

What UST system meets the requirements for secondary containment? -ANSDoubled
wall tanks

According to title 23; the following piping components if installed after July 1 1987 must
have secondary containment -ANSPressured product piping

Considered "pipe" on tanks installed after July 1 2003 -ANSPressured product piping
and below ground vapor recovery

Under dispenser containment (UDC) was required for all UST systems by -
ANSDecember 31 2003

System for exchanging gas vapors in a storage tank and product in a fuel delivery truck
-ANSStage 1 vapor recovery

An approved method for non visual monitoring for existing UST systems. -
ANSStatistical Inventory Reconciliation (SIR)

ATG must be capable for detecting a release of ? -ANS.2 gallons per hour

, Manual inventory reconciliation. -ANSNo longer an approved method for non visual
monitoring on existing UST systems

Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of tetecting a leak of ? -ANS3 gallons per hour at 10 psi

ATG should be programmed to test the tank ? -ANSAt least monthly

According to PEI RP 300 a combustible gas can be used to ? -ANSDetect vapor leaks
in a vapor recovery system.

According to PEI RP 300. A written scope of work for vapor recovery installation should
include? -ANSConstruction plans

Positive shut off overfill protection device must stop the flow of fuel when the tank is no
more then ? -ANS95% full

According to EO VR 201 A What could cause a nozzle shut off mechanism or
malfunction? -ANSDepended filter seal damage

According to VR 201 A Breakaway reconnection must be ? -ANSLogged in GDF log

According to PEI RP 300 the following method of documenting piping location is NOT to
? -ANSSketch a diagram on the inside cover of vapor recovery equipment manual

According to PEI RP 300 as built drawing or pictures of the underground pipping and
other components shall be ? -ANSMaintained as long as UST is in service

According to EO VR 101 E maintance records are required to include? -ANSName and
designated UST operator .

The Phil-Tite EVR phase 1 system require that vapor vent pipes at any UST system be -
ANSUsed with no more then 3 p/v valves

According to EO VR 2010 after installing a new spout assembly in the Healy 900 nozzle
the following test must be conducted ? -ANSNozzle dispensing shut off test

According to Healy EO VR 201 A a vapor recovery record are to be maintained by? -
ANSGasoline dispensing facility operator
(GDF)

how many feet within a public drinking well require an enhanced leak detection test -
ANS1000 feet

What are the components of the Fire Triangle ? -ANSFuel Ignition source oxygen

Geschreven voor

Instelling
California UST
Vak
California UST

Documentinformatie

Geüpload op
20 augustus 2025
Aantal pagina's
5
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€11,51
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
annn15671

Maak kennis met de verkoper

Seller avatar
annn15671 Chamberlain College Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
1 jaar
Aantal volgers
0
Documenten
845
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen