NYC HIGH PRESSURE STEAM EXAM REVIEW QUESTIONSWITH CORRECT SOLUTIONS UPDATED 2025/2026 SYLLABUS ALREADY GRADED!!100% GUARANTEED PASS!!!BRAND NEW VERSION 1. Boilers have 2 bottom blow downs when the MAWP exceeds-------- PSI - ANSWER 100 PSIG 2. What schedule pipe can you use on boiler blow down lines? - ANSWER Schedule 80 3. What is the Maximum size of a blow down valve? Minimum size and less than how many sq feet. - ANSWER MAX 2 1/2", MIN 1" ( less than 100 sq ft min 3/4". HP Code: 14-9.27b,2 4. All boiler fittings are what standard? - ANSWER ASME 5. How many gauge cocks are on a boiler with LESS than 36 " and 100 sq ft of surface? - ANSWER 2. HP Code: 14-9, 18,b 6. How many gauge cocks are on a boiler with OVER 36" and more than 100 sq ft of surface? - ANSWER 3 7. What size are the gauge cocks on a boiler? - ANSWER Not to be less than 1/2". HP Code: 14-9.18,c. 8. How many gauge cocks does a boiler have with two water glasses on the same horizontal line? - ANSWER 2 Cocks at 1/2". HP Code: 14-9.18,a 9. Any valve used as a shutoff to a water column shall be sealed ----- and ------ - ANSWER Sealed Open and LOCKED. HP Code: 14-9.17,b 10.HRT Fire tube boiler what is the minimum water level in a gage glass? - ANSWER " Lowest reading in the water gage glass there shall be at least THREE INCHES of water over the highest point of the tube, flues, or crown sheets". HP Code: 14-9.16,e 11.What can be attached to the same outlet from a super heater that is used also for the safety valve connection? - ANSWER Soot Blower 12.A safety valve over 3" and over 15 PSIG shall have what type of inlet connection? - ANSWER Flanged or Welded 13.The discharge of safety valves or safety relief valves shall be located so as to prevent --------- - ANSWER Scalding. HP Code: 14-9.1,c,4 14.Safety valve plate has what? - ANSWER Name, Manufacturer #, Size, Seat, Pressure ( PSIG ), Year built, Capacity, Capacity life, ASME. HP Code: 14-9.8 15.Where in isolation transformer is provided, one conductor of the secondary winding shall be? - ANSWER GROUNDED. NYC Mech: 1006.8 16.When would a heat exchanger not need shutoff valves? - ANSWER When it is integral with the boiler

Meer zien Lees minder
Instelling
NYC HIGH PRESSURE STEAM
Vak
NYC HIGH PRESSURE STEAM

Voorbeeld van de inhoud

NYC HIGH PRESSURE STEAM EXAM
REVIEW QUESTIONSWITH CORRECT
SOLUTIONS UPDATED 2025/2026
SYLLABUS ALREADY GRADED!!100%
GUARANTEED PASS!!!<<BRAND
NEW VERSION>>
1. Boilers have 2 bottom blow downs when the MAWP exceeds-------- PSI -
ANSWER ✓ 100 PSIG

2. What schedule pipe can you use on boiler blow down lines? - ANSWER ✓
Schedule 80

3. What is the Maximum size of a blow down valve? Minimum size and less
than how many sq feet. - ANSWER ✓ MAX 2 1/2", MIN 1" ( less than 100
sq ft min 3/4". HP Code: 14-9.27b,2

4. All boiler fittings are what standard? - ANSWER ✓ ASME

5. How many gauge cocks are on a boiler with LESS than 36 " and 100 sq ft of
surface? - ANSWER ✓ 2. HP Code: 14-9, 18,b

6. How many gauge cocks are on a boiler with OVER 36" and more than 100
sq ft of surface? - ANSWER ✓ 3

7. What size are the gauge cocks on a boiler? - ANSWER ✓ Not to be less than
1/2". HP Code: 14-9.18,c.

8. How many gauge cocks does a boiler have with two water glasses on the
same horizontal line? - ANSWER ✓ 2 Cocks at 1/2". HP Code: 14-9.18,a

,9. Any valve used as a shutoff to a water column shall be sealed ----- and ------
- ANSWER ✓ Sealed Open and LOCKED. HP Code: 14-9.17,b

10.HRT Fire tube boiler what is the minimum water level in a gage glass? -
ANSWER ✓ " Lowest reading in the water gage glass there shall be at least
THREE INCHES of water over the highest point of the tube, flues, or crown
sheets". HP Code: 14-9.16,e

11.What can be attached to the same outlet from a super heater that is used also
for the safety valve connection? - ANSWER ✓ Soot Blower

12.A safety valve over 3" and over 15 PSIG shall have what type of inlet
connection? - ANSWER ✓ Flanged or Welded

13.The discharge of safety valves or safety relief valves shall be located so as to
prevent --------- - ANSWER ✓ Scalding. HP Code: 14-9.1,c,4

14.Safety valve plate has what? - ANSWER ✓ Name, Manufacturer #, Size,
Seat, Pressure ( PSIG ), Year built, Capacity, Capacity life, ASME. HP
Code: 14-9.8

15.Where in isolation transformer is provided, one conductor of the secondary
winding shall be? - ANSWER ✓ GROUNDED. NYC Mech: 1006.8

16.When would a heat exchanger not need shutoff valves? - ANSWER ✓ When
it is integral with the boiler

17.The flash point in a Hydronic system is -- F* above the maximum operating
temperature - ANSWER ✓ 50* F

18.The slope of piping for condensate is --% - ANSWER ✓ 1%

19.Piping Support ( Mechanical Code 2008 ) - ANSWER ✓ A. Steel pipe
support are spaced every 12 FT HORIZONTAL and 15 FT VERTICAL
B. Steel tube support are spaced every 8 FT HORIZONTAL and 10 FT
VERTICAL

20.What is the Inspection Frequency of a Boiler?

, A. Low Pressure Steam Internal and External?
B. Low Pressure Hot Water Internal and External?
C. High Pressure Steam Internal and External?
D. High Pressure Hot Water Boiler? - ANSWER ✓ A. Internal every 3
years and External every 2 years
B. Internal every 5 years and External every 2 years
C. Internal every 1 year and External every 1 year.

21.How is the Main Steam pressure gauges tested? - ANSWER ✓ With an
Inspectors Gage. HP Code: 14-9.21, 14-10.19/NYC Mech:1011.2
22.The maximum blow down for a safety valve on a forced flow steam
generator or high temperature water boiler shall be of what percent of the set
pressure? - ANSWER ✓ 10%. HP Code: 14-9.12

23.Who oversees the code for any plumbing installations? - ANSWER ✓ The
NYC Plumbing Code NYC Mech: 1002.1

24.When will anchorage or guides be inspected? - ANSWER ✓ Annually. NYC
Mech: 1210.3.1.2

25.How many brass washout plugs does a miniature boiler have? - ANSWER ✓
Not less than 3 Brass Washout Plugs 1 inches in size. HP Code 14-11.5

26.How often are high pressure piping expansion joints inspected? - ANSWER
✓ Weekly RCNY: 20-02 a.2.i (HP steam piping). NYC Mech: 1210.3.1
(hydronics - monthly)

27.How long should a Hydronic System be pressure tested for? - ANSWER ✓ 2
hours at no less than 100 PSIG. NYC Mech: 1208.1

28.How is a gauge protected from excessive pressure? - ANSWER ✓ Shut off
Cock RCNY: 20-03 c,7

29.Who is authorized in witnessing a test on a gas piping system? - ANSWER
✓ Plumbing Inspector, Architect, Licensed PE, Master Plumber, or Agency
by the D.O.B RCNY 20-01 a,1,2

Geschreven voor

Instelling
NYC HIGH PRESSURE STEAM
Vak
NYC HIGH PRESSURE STEAM

Documentinformatie

Geüpload op
23 september 2025
Aantal pagina's
25
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€14,21
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SmartscoreAaron Chicago State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
79
Lid sinds
1 jaar
Aantal volgers
6
Documenten
4081
Laatst verkocht
1 dag geleden
SMARTSCORES LIBRARY

Get top-tier academic support for Psychology, Nursing, Business, Engineering, HRM, Math, and more. Our team of professional tutors delivers high-quality homework, quiz, and exam assistance—ensuring scholarly excellence and grade-boosting results. Trust our collaborative expertise to help you succeed in any course at U.S.A Institutions.

3,1

7 beoordelingen

5
3
4
1
3
0
2
0
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen