Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Plumbing Code Exam Questions Answered Correctly Latest Update

Beoordeling
-
Verkocht
-
Pagina's
44
Cijfer
A+
Geüpload op
29-09-2025
Geschreven in
2025/2026

Plumbing Code Exam Questions Answered Correctly Latest Update Definition Any combination of fixtures, not to exceed one water closet, 2 lavs, either 1 bathtub or bath/ shower combo, and 1 shower. May include bidet & floor drain. - Answers Bathroom Group Definition A pipe that makes an angle of more than 45 degrees with the vertical is considered? - Answers Vertical Pipe A device and system of piping that maintains a water seal in a remote trap is called? - Answers Trap Primer Table 1002.2 The developed length of a 2" trap arm, from the trap weir to the inner edge of the vent shall not exceed how many feet? - Answers 5 feet Definition Having access thereto, but which first may require the removal of an access panel, door, or similar obstruction. - Answers Accessible Definition Having direct access without the necessity of removing a panel, door, or similar obstruction. - Answers Readily Accessible Table 703.2 How many Fixture Units may a 1 1/2" vent pipe serve? - Answers 8 fixture units Table 703.2 *Note 6 Vent piping should not exceed ___________ of the total permitted length horizontally. - Answers 1/3 Table 703.2 *Note 6 The vent shall not be less than _______ or _______. - Answers 1 1/4" or less than 1/2 the diameter of the drain. Definition Water at a temperature exceeding or equal to 100F - Answers Hot water Definition The slope or fall of a line of pipe in reference to a horizontal plane. - Answers Grade Definition The pipe carrying potable water from the water meter or other source of water supply to a building. - Answers Building Supply Definition A room equipped with only a water closet and lavatory. - Answers Half Bathroom Table 1002.2 The max distance of a 2" trap arm shall not exceed ____. - Answers 5 feet or 60" The scale on a set of plans is 1/8 inch= 1 foot. The actual length of a water line with plan of 5" would be ___________ feet. - Answers 40 feet The developed length of a 1 1/2" trap arm shall not exceed ______________. - Answers 3ft 6in or 42 inches What is the max fixture unit load size for a 2" horizontal drain? What is the max fixture unit load size for a 2" vertical drain? - Answers Horizontal: 8fu Vertical: 16fu 605.1.2 Flared Joints Flaring tools are used to make joints for __________ or _________. - Answers soft copper or copper alloy Who needs to inspect and approve the plumbing system before it is concealed and covered? - Answers Authority Having Jurisdiction (AHJ) 905.3 Vent Pipe Rise Vent pipes may offset horizontally when the distance above the overflow level of the fixture is not less than ____________. - Answers 6" 105.2.3 Inspection Requests The Authority Having Jurisdiction shall be permitted to require a ____________ notice before inspection. - Answers 24 hours 811.1 Pretreatment Copper tubing and fittings shall be permitted to be used with DWV systems except for ____________. - Answers Chemical waste How is Pex defined? - Answers Cross-linked polyethylene The max vertical distance for a tailpiece allowed between a fixture and the trap weir is _____________. - Answers 24" Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the roof at least __________. - Answers 6 inches All indirect waste piping that requires an airgap shall discharge into the building drainage system through ______________. - Answers A drainage air gap of 1" minimum 604.13 Water Heater Connectors Pex tubing shall not be installed within the first __________ of piping connected to a water heater. - Answers 18" 706.3 Horizontal to Horizontal A horizontal drainage line connecting with other horizontal drainage lines shall enter through a __________, __________, __________, or other approved fittings of equivalent sweep. - Answers 45 degree wye branch, combo wye, one-eighth bend branches One gallon of water weighs approximately _______. - Answers 8.34 lbs 910.4 Size The cleanout for a 4" diameter drain pipe shall not be smaller than ________. - Answers 3 1/2" Stand pipe receptors for clothes washers shall extend above the trap no less than _______. - Answers 18 inches App A A104.1 The minimum residual water pressure that shall be maintained at the highest fixtures in the supply system shall not be less than ______. - Answers 8 psi Definition What is a trap that does not maintain a proper trap seal? - Answers Insanitary What is Chlorinated Polyvinyl Chloride? - Answers CPVC Definitions A quantity in terms of which the load production effects on the plumbing system. - Answers Fixture Units (FU) Is 95F considered hot water? - Answers No What is the condition that is contrary to sanitary principles or is injurious to health? - Answers Insanitary Definition The principal artery of a system of continuous piping to which banches may be connected - Answers Main 404.2 Overflows The overflow pipe from a fixture shall be connected on the _______________. - Answers House or inlet side of the trap 409.2 Waste Outlet The diameter of a waste outlet and fixture tailpiece of a bathtub shall not be less than ___________. - Answers 1 1/2" diameter Does unsanitary & insanitary share the same meaning? - Answers Yes

Meer zien Lees minder
Instelling
Plumbing Code
Vak
Plumbing Code

Voorbeeld van de inhoud

Plumbing Code Exam Questions Answered Correctly Latest Update 2025-2026

Definition



Any combination of fixtures, not to exceed one water closet, 2 lavs, either 1 bathtub or bath/
shower combo, and 1 shower. May include bidet & floor drain. - Answers Bathroom Group

Definition



A pipe that makes an angle of more than 45 degrees with the vertical is considered? - Answers
Vertical Pipe

A device and system of piping that maintains a water seal in a remote trap is called? - Answers
Trap Primer

Table 1002.2



The developed length of a 2" trap arm, from the trap weir to the inner edge of the vent shall not
exceed how many feet? - Answers 5 feet

Definition



Having access thereto, but which first may require the removal of an access panel, door, or
similar obstruction. - Answers Accessible

Definition



Having direct access without the necessity of removing a panel, door, or similar obstruction. -
Answers Readily Accessible

Table 703.2



How many Fixture Units may a 1 1/2" vent pipe serve? - Answers 8 fixture units

Table 703.2

*Note 6

,Vent piping should not exceed ___________ of the total permitted length horizontally. - Answers
1/3

Table 703.2

*Note 6



The vent shall not be less than _______ or _______. - Answers 1 1/4"

or

less than 1/2 the diameter of the drain.

Definition



Water at a temperature exceeding or equal to 100F - Answers Hot water

Definition



The slope or fall of a line of pipe in reference to a horizontal plane. - Answers Grade

Definition



The pipe carrying potable water from the water meter or other source of water supply to a
building. - Answers Building Supply

Definition



A room equipped with only a water closet and lavatory. - Answers Half Bathroom

Table 1002.2



The max distance of a 2" trap arm shall not exceed ____. - Answers 5 feet

or

,60"

The scale on a set of plans is 1/8 inch= 1 foot. The actual length of a water line with plan of 5"
would be ___________ feet. - Answers 40 feet

The developed length of a 1 1/2" trap arm shall not exceed ______________. - Answers 3ft 6in

or

42 inches

What is the max fixture unit load size for a 2" horizontal drain?



What is the max fixture unit load size for a 2" vertical drain? - Answers Horizontal: 8fu



Vertical: 16fu

605.1.2 Flared Joints



Flaring tools are used to make joints for __________ or _________. - Answers soft copper or
copper alloy

Who needs to inspect and approve the plumbing system before it is concealed and covered? -
Answers Authority Having Jurisdiction (AHJ)

905.3 Vent Pipe Rise



Vent pipes may offset horizontally when the distance above the overflow level of the fixture is
not less than ____________. - Answers 6"

105.2.3 Inspection Requests



The Authority Having Jurisdiction shall be permitted to require a ____________ notice before
inspection. - Answers 24 hours

811.1 Pretreatment

, Copper tubing and fittings shall be permitted to be used with DWV systems except for
____________. - Answers Chemical waste

How is Pex defined? - Answers Cross-linked polyethylene

The max vertical distance for a tailpiece allowed between a fixture and the trap weir is
_____________. - Answers 24"

Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the
roof at least __________. - Answers 6 inches

All indirect waste piping that requires an airgap shall discharge into the building drainage
system through ______________. - Answers A drainage air gap of 1" minimum

604.13 Water Heater Connectors



Pex tubing shall not be installed within the first __________ of piping connected to a water heater.
- Answers 18"

706.3 Horizontal to Horizontal



A horizontal drainage line connecting with other horizontal drainage lines shall enter through a
__________, __________, __________, or other approved fittings of equivalent sweep. - Answers 45
degree wye branch, combo wye, one-eighth bend branches

One gallon of water weighs approximately _______. - Answers 8.34 lbs

910.4 Size



The cleanout for a 4" diameter drain pipe shall not be smaller than ________. - Answers 3 1/2"

Stand pipe receptors for clothes washers shall extend above the trap no less than _______. -
Answers 18 inches

App A A104.1



The minimum residual water pressure that shall be maintained at the highest fixtures in the
supply system shall not be less than ______. - Answers 8 psi

Definition

Geschreven voor

Instelling
Plumbing Code
Vak
Plumbing Code

Documentinformatie

Geüpload op
29 september 2025
Aantal pagina's
44
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,67
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TutorJosh Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
450
Lid sinds
1 jaar
Aantal volgers
16
Documenten
32010
Laatst verkocht
1 dag geleden
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3,5

73 beoordelingen

5
26
4
16
3
14
2
1
1
16

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen