Definition
Any combination of fixtures, not to exceed one water closet, 2 lavs, either 1 bathtub or bath/
shower combo, and 1 shower. May include bidet & floor drain. - Answers Bathroom Group
Definition
A pipe that makes an angle of more than 45 degrees with the vertical is considered? - Answers
Vertical Pipe
A device and system of piping that maintains a water seal in a remote trap is called? - Answers
Trap Primer
Table 1002.2
The developed length of a 2" trap arm, from the trap weir to the inner edge of the vent shall not
exceed how many feet? - Answers 5 feet
Definition
Having access thereto, but which first may require the removal of an access panel, door, or
similar obstruction. - Answers Accessible
Definition
Having direct access without the necessity of removing a panel, door, or similar obstruction. -
Answers Readily Accessible
Table 703.2
How many Fixture Units may a 1 1/2" vent pipe serve? - Answers 8 fixture units
Table 703.2
*Note 6
,Vent piping should not exceed ___________ of the total permitted length horizontally. - Answers
1/3
Table 703.2
*Note 6
The vent shall not be less than _______ or _______. - Answers 1 1/4"
or
less than 1/2 the diameter of the drain.
Definition
Water at a temperature exceeding or equal to 100F - Answers Hot water
Definition
The slope or fall of a line of pipe in reference to a horizontal plane. - Answers Grade
Definition
The pipe carrying potable water from the water meter or other source of water supply to a
building. - Answers Building Supply
Definition
A room equipped with only a water closet and lavatory. - Answers Half Bathroom
Table 1002.2
The max distance of a 2" trap arm shall not exceed ____. - Answers 5 feet
or
,60"
The scale on a set of plans is 1/8 inch= 1 foot. The actual length of a water line with plan of 5"
would be ___________ feet. - Answers 40 feet
The developed length of a 1 1/2" trap arm shall not exceed ______________. - Answers 3ft 6in
or
42 inches
What is the max fixture unit load size for a 2" horizontal drain?
What is the max fixture unit load size for a 2" vertical drain? - Answers Horizontal: 8fu
Vertical: 16fu
605.1.2 Flared Joints
Flaring tools are used to make joints for __________ or _________. - Answers soft copper or
copper alloy
Who needs to inspect and approve the plumbing system before it is concealed and covered? -
Answers Authority Having Jurisdiction (AHJ)
905.3 Vent Pipe Rise
Vent pipes may offset horizontally when the distance above the overflow level of the fixture is
not less than ____________. - Answers 6"
105.2.3 Inspection Requests
The Authority Having Jurisdiction shall be permitted to require a ____________ notice before
inspection. - Answers 24 hours
811.1 Pretreatment
, Copper tubing and fittings shall be permitted to be used with DWV systems except for
____________. - Answers Chemical waste
How is Pex defined? - Answers Cross-linked polyethylene
The max vertical distance for a tailpiece allowed between a fixture and the trap weir is
_____________. - Answers 24"
Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the
roof at least __________. - Answers 6 inches
All indirect waste piping that requires an airgap shall discharge into the building drainage
system through ______________. - Answers A drainage air gap of 1" minimum
604.13 Water Heater Connectors
Pex tubing shall not be installed within the first __________ of piping connected to a water heater.
- Answers 18"
706.3 Horizontal to Horizontal
A horizontal drainage line connecting with other horizontal drainage lines shall enter through a
__________, __________, __________, or other approved fittings of equivalent sweep. - Answers 45
degree wye branch, combo wye, one-eighth bend branches
One gallon of water weighs approximately _______. - Answers 8.34 lbs
910.4 Size
The cleanout for a 4" diameter drain pipe shall not be smaller than ________. - Answers 3 1/2"
Stand pipe receptors for clothes washers shall extend above the trap no less than _______. -
Answers 18 inches
App A A104.1
The minimum residual water pressure that shall be maintained at the highest fixtures in the
supply system shall not be less than ______. - Answers 8 psi