Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Rhode Island Journeyman Plumber Exam ACTUAL QUESTIONS AND CORRECT ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
16
Cijfer
A+
Geüpload op
03-11-2025
Geschreven in
2025/2026

Rhode Island Journeyman Plumber Exam ACTUAL QUESTIONS AND CORRECT ANSWERS Plumbing Code Regulation SBC-3 - CORRECT ANSWERS Plumbing Code is known as: 4' 6" Below Grade - CORRECT ANSWERS State of Rhode Island Water Services Shall Be Installed Not Less Than: Insulated/Heated or Both - CORRECT ANSWERS areas subject to freezing must: 36" Below Grade - CORRECT ANSWERS Piping installed in exterior walls or Building Sewers connected to a public sewer

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Rhode Island Journeyman Plumber Exam
ACTUAL QUESTIONS AND CORRECT
ANSWERS
Plumbing Code Regulation SBC-3 - CORRECT ANSWERS State of Rhode Island
Plumbing Code is known as:



4' 6" Below Grade - CORRECT ANSWERS Water Services Shall Be Installed Not Less
Than:



Insulated/Heated or Both - CORRECT ANSWERS Piping installed in exterior walls or
areas subject to freezing must:



36" Below Grade - CORRECT ANSWERS Building Sewers connected to a public sewer
shall have a minimum coverage of:



Under a water heater 6 gallons or greater that is elevated - CORRECT ANSWERS A safe
waste pan shall be installed



2" deep with 2" clearance around heater - CORRECT ANSWERS A safe waste pan shall
be at least



10' undisturbed compacted earth - CORRECT ANSWERS Water service piping and
building drain/sewer shall be separated by:



Water line is installed minimum 12" above sewer line at highest point - CORRECT
ANSWERS Water service separation distance is not required if:

,50' - CORRECT ANSWERS Distance for a septic tank/sewer to a private water
supply(well) is:



6"below the roof with an approved fitting - CORRECT ANSWERS Where frost closure is
common an increase in vent size shall take place:



"V" zone (subject to wave heights in excess of 3') - CORRECT ANSWERS High Hazard
flood zone is:



8.0% Lead - CORRECT ANSWERS Lead free pipe and fittings contain less than:



110 degrees - CORRECT ANSWERS Hot water is water at temperature greater than or
equal to:



0.2% Lead - CORRECT ANSWERS Lead free solder and flux contain no more than



0.5 inches - CORRECT ANSWERS Strainer plates on drain lines for rodent proofing must
have openings:



Two pipe size greater than the pipe passing through it - CORRECT ANSWERS Sleeves
for pipes passing through foundation walls or under footings shall be:



500' - CORRECT ANSWERS Travel distance to toilet facilities in
merchantile/occupancies are:



300' - CORRECT ANSWERS Travel distance to toilet facilities in covered malls are:

, 15" - CORRECT ANSWERS Water closets, bidets or lavatories shall have a clearance
from center of fixture to wall of:



21" - CORRECT ANSWERS The required clearance from front of fixture to a wall, door
or other fixture is:



3" - CORRECT ANSWERS Minimum size floor drains for public laundries or central
washing facilities is:



1 1/2" - CORRECT ANSWERS Shower waste outlets shall be minimum of:



3" - CORRECT ANSWERS Minimum size removable strainer for shower compartments
are:



.25 inches - CORRECT ANSWERS Minimum size floor drain strainer opening is:



4 pounds per square foot - CORRECT ANSWERS Sheet lead shall not weigh less than:



12 ounces per square foot - CORRECT ANSWERS Sheet copper shall not weigh less than:



67% - CORRECT ANSWERS Urinals shall not be substituted for more than what percent
of water closets?



120 degrees - CORRECT ANSWERS Shower and Tub/Shower valves maximum hot water
setting is:

Geschreven voor

Vak

Documentinformatie

Geüpload op
3 november 2025
Aantal pagina's
16
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€10,64
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
GENIOUSTOPCLASS
3,0
(1)

Maak kennis met de verkoper

Seller avatar
GENIOUSTOPCLASS Stanford
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
11 maanden
Aantal volgers
0
Documenten
1857
Laatst verkocht
7 maanden geleden
ACADEMIC EXAMS PLATFORM

I create high-quality, easy-to-understand academic documents to help students learn faster and perform better. My materials are well-researched, clearly organized, and cover key exam topics to make studying simple and effective.

3,0

1 beoordelingen

5
0
4
0
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen