1.According to the IBC, the "blank" is to hire the special inspector.: owner or owners agent. 2009 IBC Section 1704.1
2.According to the IBC, the "blank" is the responsible for the approval of a
person's qualifications to act as a special inspector.: code official. 2009 IBC, Section 1704.1 3. According to the IBC, discrepancy
corrections are made known to the building official by:: final report. 2009 IBC, Section1704.1.2
4.When is the code official to be made aware of a discrepancy found during a
special inspection?: If it is not corrected by the contractor. 2009 IBC, Section 1704.1.2
5.According to the Model Program for Special Inspection, the special inspector is to document work that is nonconforming:: In a
written report - Section II B 4 - Model Programs 6. According to the Model Program for Special Inspection, the special inspector
is to prepare written report of inspection:: After each inspection visit - Section II B 5 - Model Programs
7. According to the Model Program for Special Inspection, which of the following items does not need to be included in each
inspection report?: Description of discussions with the contractor - Section B 5 - Model Programs
8. According to the Specification for Structural Joints using high strength bolts,
the nominal diameter of standard bolt holes shall be how much larger than the
nominal bolt diameter?: 1/16 inch - Specification for Structural Joints Table 3.1
9. Discrepancies in the work shall be brought to the immediate attention of the
"blank" for corrective action.: the contractor - 2009 IBC, Section 1704.1.2.
10. The special inspector shall furnish inspection reports to the "blank" and to the "blank"?: Building Official and Registered
Design professional
11. The special inspector shall provide continuos inspection of:: Single-pass fillet welds greater than 5/16 inch in size - 2099
IBC, Table 1704.3, Item 5.3
12. The special inspections required by this code are not required where the work is done on the premise of a?: Approved
fabricator - 2009 IBC, Section 1704.2.2
13. The special inspection of the steel fabrication process shall not be required where the fabricator does not perform any?:
heating operations - 2009 IBC, Section 1704.3,
Exceptions # 1
14. According to the Specifications for Structural Steel Buildings, ASTM Standard "blank" is to be used for the material test for
steel sheets.: A568 - Section A31,
Specifications for Structural Steel Buildings
15. According to the Specifications for Structural Steel Buildings, the "blank" conducts the material tests for identification of
the structural steel.: Fabricator or
Testing Laboratory - Section A31, Specifications for Structural Steel Buildings.
, 16. According to the Specifications for Structural Steel Buildings, which of the following steel members are allowed to be
unidentified steel?: Unimportant members,
where their physical properties and weldability would not affect the structure strength - Section A31b, Specifications for
Structural Steel Buildings
17. According to the Code of Standard Practice for Steel Buildings and Bridges,
how is steel of special material to be identified?: It is marked by the supplier - Section 5.1.1, Code of Standard Practice for Steel
Buildings and Bridges
18. According to the Code of Standard Practice for Steel Buildings and Bridges,
how are fabricators stock steel material identified?: Certified mill test reports - Section 5.2.2 - Code of Standard Practice for Steel
Buildings and Bridges
19. According to the Specification for Structural Steel Buildings, what ASTM
Standard would apply to a sample for structural steel pipe?: A53 - Section A31a -
Specification for Structural Steel Buildings
20. According to the Code of Standard Practice for Steel Buildings and Bridges,
the number of samples required to be tested for structural steel is:: The number
specified by the ASTM specification - Section 5.1.1 - Code of Standard Practice for Steel Buildings and Bridges
21. According to the Specification for Structural Steel Buildings, which ASTM standard would apply to a sample for structural
steel plates?: A36, A283, and A242 -
Section A31a - Specification for Structural Steel Buildings
22. According to the Specification for Structural Steel Buildings, "blank" tests are
required for samples for built-up sections consisting of plates over 2 inches in
thickness.: Charpy V-notch testing - Section A31d, Specification for Structural Steel Buildings
23. According to the Specification for Structural Steel Buildings, ASTM standard "blank" would apply to a sample for structural
steel bars.: A36, A529, and A572 -
Specification for Structural Steel Buildings
24 Steel furnished for structural load-carrying purposes shall be properly :: Identified - 2009 IBC, Section 2203.1
25. Steel that is not readily identifiable as to grade by marking and test records shall be:: tested - 2009 IBC, Section 2203.1
26. Where materials or assemblies are required by this code to be labeled, such material and assemblies shall be labeled by::
An approved agency - 2009 IBC, Section 1703.5
27. Inspection of the steel frame for compliance with the approved construction documents should verify:: Member location,
Bracing, and Stiffening - 2009 IBC, Section 1704.3.2. 28. Continuous inspection of bolt pre-tensioning is required when using:: The
calibrated wrench method - 2009 IBC, Section 1704.3.3.3.