THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS.
AND TO DETERMINE QUALIFICATIONS. Ans: — OWNER
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED
ON PREMISES FOR A MIN. OF __________ YEARS. Ans: — 3
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO
COMPLY WITH REQUIREMENTS. Ans: — IMPAIRMENT
COORDINATOR
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN
________ FLOOR(S) ARE CONSIDERED PLANNED REMOVAL FROM
SERVICE. Ans: — 1
SHUTDOWNS AFFECTING MORE THAN _________ FLOOR(S) ARE
CONSIDERED UNPLANNED OUT OF SERVICE CONDITIONS. Ans: —
1
NOTIFICATION TO FDNY IS NOT REQUIRED, PROVIDED SYSTEM IS
RETURNED TO SERVICE WITHIN ______ HOURS. Ans: — 8
FOR UNPLANNED REMOVAL FROM SERVICE, THE COF HOLDER
SHALL IMMEDIATELY REPORT CONDITION TO THE ___________
AND THE FIRE DEPT. Ans: — OWNER OF THE BUILDING
IF A MINOR DEFECT IS OBSERVED, IT SHALL BE CORRECTED
WITHIN _________ DAYS OR IT WILL BE CONSIDERED AN
IMPAIRMENT. Ans: — 30
WHAT DOES "OOS" STAND FOR? Ans: — OUT OF SERVICE
OOS SYSTEMS SHALL BE IDENTIFIED BY PLACING ________ AT FIRE
DEPT. CONNECTIONS, SYS. CONTROL VALVES, AND FIRE
COMMAND CENTER Ans: — TAGS




© 2025 All rights reserved

, 2 | Page

A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL
VALVE AND ANY SECTIONAL VALVES. Ans: — MASTER FIRE
SUPPRESSION PIPING CONTRACTOR
__________ SHALL BE POSTED ON THE TAG INDICATING BOTH
STATIC AND FLOW PRESSURES BEFORE AND AFTER. Ans: —
DRAIN TEST RESULTS
GREEN TAGS INDICATE THAT __________. Ans: — NO IMPAIRMENT
WAS FOUND
GREEN TAGS WILL BE PLACED ON THE ____________. Ans: — MAIN
CONTROL VALVE
SYSTEMS PARTIALLY OR FULLY OUT OF SERVICE SHALL HAVE A
____________ TAG PLACED ON THE MAIN CONTROL VALVE. Ans: —
RED
A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON
CONNECTIONS TO INDICATE THE SYSTEM IS FULLY OUT OF
SERVICE. Ans: — WHITE
A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON
CONNECTIONS TO INDICATE THE SYSTEM IS PARTIALLY OUT OF
SERVICE. Ans: — BLUE
THE IMPAIRMENT COORDINATOR WILL NOTIFY THE ___________
CARRIER, CENTRAL STATION AND OCCUPANTS. Ans: —
INSURANCE
PRIOR TO RETURNING A SYS. TO SERVICE, THE ___________ SHALL
ENSURE THAT NECESSARY TESTS AND INSPECTIONS ARE
CONDUCTED. Ans: — IMPAIRMENT COORDINATOR
GLYCERIN NOT GREATER THAN _________ PERCENT OR GLYCOL
NOT GREATHER THAN ________ PERCENT SHALL BE USED TO
PROTECT FROM FREEZING. Ans: — 50, 40
THE COF NUMBER AND SIGNATURE OF COF HOLDER SHALL BE
POSTED NEAR THE ____________. Ans: — MAIN CONTROL VALVE




© 2025 All rights reserved

, 3 | Page

__________ SHALL BE READILY AVAILABLE TO ANY
REPRESENTATIVE OF THE FIRE DEPT. THESE ARE TO BE
MAINTAINED ON SITE FOR 3 YEARS. Ans: — RECORDS
FAILURE TO MAKE INSPECTIONS MAY RESULT IN __________ OF
THE COF AND COURT PROCEEDINGS. Ans: — REVOCATION
THE COF HOLDER MAY INSPECT, TEST, AND PERFORM ROUTINE
MX IF THEY HOLD THE FOLLOWING CERTS: Ans: —
REFRIGERATION OPERATING ENGINEER, HIGH PRESSURE
OPERATING ENGINEER, AND NYS HIGH PRESSURE OPERATING
ENGINEER.
A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE
STANDPIPE AND SPRINKLER SYSTEMS. Ans: — MASTER FIRE
SUPPRESSION PIPING CONTRACTOR (MFSPC)
A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL
OCCUPANCIES WITH _________ SPRINKLER HEADS OR LESS. Ans: —
30
ABOUT ______ PERCENT OF FIRES ARE EXTINGUISHED OR
CONTROLLED WHEN SPRINKLERS ARE INSTALLED. Ans: — 96
WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF _______
TO PREVENT THE SYSTEM FROM FREEZING. Ans: — 40
FAHRENHEIT
__________ VALVES ARE NO LONGER PERMITTED TO BE
INSTALLED. Ans: — COLD WEATHER
________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM
CANNOT BE HEATED TO PREVENT FREEZING. Ans: — DRY PIPE
THE DROP IN ________ CAUSES A SPECIAL DRY PIPE VALVE TO
OPEN. Ans: — AIR PRESSURE
IN BUILDINGS WHERE LIFE HAZARD IS HIGH (SCHOOLS,
HOSPITALS) THE ALARM IS TRANSMITTED DIRECTLY TO THE
_________. Ans: — FIRE DEPARTMENT
DRY PIPE VALVES ARE OF A ______ DESIGN. Ans: — CLAPPER



© 2025 All rights reserved

Geschreven voor

Instelling
S-12
Vak
S-12

Documentinformatie

Geüpload op
26 november 2025
Aantal pagina's
19
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€12,37
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Axpert NURSING
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
540
Lid sinds
2 jaar
Aantal volgers
167
Documenten
28074
Laatst verkocht
3 dagen geleden
Study Smart

Your one-stop resource for high-quality, exam-focused study materials. Here, you'll find expertly crafted summaries, past exam papers, notes, and assignments tailored to help you succeed in your courses. Every document is written with clarity, accuracy, and exam performance in mind—saving you hours of studying and helping you boost your grades. ✅ Clear and well-structured content ✅ Covers key exam topics and common questions ✅ Trusted by students for academic success ✅ Instant downloads and affordable prices Whether you're cramming for finals or just staying ahead in class, my materials are designed to make your studying smarter, not harder. Take a look around and get the edge you need!

Lees meer Lees minder
3,8

124 beoordelingen

5
55
4
26
3
22
2
4
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen