Page |1


NEC Journeyman Test Practice Questions
and Correct Answers/ Latest Update /
Already Graded
Devices __ for bonding the metallic frames of PV modules shall be
permitted to bond the exposed metallic frames of PV modules to the
metallic frames of adjacent PV modules.

Ans: 690.43(B) All of these: Listed, Labled, Identified,


Where exposed and subject to physical damage, PV array equipment
grounding conductors smaller than 4 AWG shall be protected by a
raceway or cable armor.

Ans: 250.120 (C) FALSE


Buildings/structures containing both utility service and a PV system
shall have a ________installed in accordance with 705.10.

Ans: 690.56 (B) Plaque, OR Directory


A(n) __ surge protection device shall be installed in or on the fire pump
controller.

Ans: 695.15 Listed




All rights reserved © 2025/ 2026 |

, Page |2

Emergency system equipment shall be maintained in accordance with
______.

Ans: Manufacturer's instructions AND Industry standards


Where used for emergency systems, the short-circuit current rating of
the transfer equipment, based on the specific overcurrent protective
device type and settings protecting the transfer equipment, shall be
field marked on the ______of the transfer equipment.

Ans: 700.5 (E) exterior


Emergency circuits shall be permanently marked so they will be readily
identified as a component of an emergency circuit or system and __
____.

Ans: 700.10 (A)(1)(2) All boxes and enclosures (Including
transfer switches, generators and power panel) or emergency
circuits shall be permanently marked as a component of an
emergency circuit or system AND where boxes or enclosures are
not encountered exposed cable or raceway systems shall be
permanently marked to be identified as a component of an
emergency circuit or system and intervals not to exceed 25 FT


Emergency circuits shall be permanently marked so they will be readily
identified as a component of an emergency circuit or system and
receptacles supplied from the emergency system shall have a(n)

All rights reserved © 2025/ 2026 |

, Page |3

_______ color or marking on the receptacle cover plates or the
receptacles.

Ans: 700.10(A) Distinctive


If wiring from an emergency source is used to supply emergency and
other loads, then ________ switchgear sections or switchboard
sections, with or without a common bus, or individual disconnects
mounted in separate enclosures shall be used to separate emergency
loads from all other loads.

Ans: 700.10(B)(5)(A) Separate Vertical


Wiring from an emergency source to supply emergency and other
(nonemergency) loads shall be permitted if the common bus of
separate sections of the switchgear, separate sections of the
switchboard, or the individual enclosures are supplied by single or
multiple feeders ______.

Ans: 700.10(B)(5) I AND II Without overcurrent protection at
the source AND With overcurrent protection, provided that the
overcurrent that is common to the emergency system and any
non-emergency system(s) is selectively coordinated with the
next downstream overcurrent protection device in the non -
emergency system(s)




All rights reserved © 2025/ 2026 |

, Page |4

Batteries for unit equipment for emergency systems shall be of
suitable rating and capacity to supply and maintain the total lamp load
associated with the unit for a period of at least _____ hour(s) without
the voltage falling below 87½ percent of normal battery voltage.

Ans: 700.12(C) 1 1/2


Batteries for unit equipment for emergency systems shall be of
suitable rating and capacity to supply and maintain the total lamp load
associated with the unit and the unit equipment shall supply and
maintain not less than __ percent of the initial emergency illumination
for a period of at least 1½ hours.

Ans: 700.12(I)(2)(1)(B)


A written record shall be kept of required tests and maintenance on
legally required standby systems.

Ans: 701.3(D) True


The branch-circuit overcurrent devices for legally required standby
systems shall be accessible only to ______.

Ans: 701.30 Authorized Persons




All rights reserved © 2025/ 2026 |

Geschreven voor

Instelling
NEC - Journeyman
Vak
NEC - Journeyman

Documentinformatie

Geüpload op
30 november 2025
Aantal pagina's
41
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€12,86
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Expert1 Chamberlian School of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
61
Lid sinds
1 jaar
Aantal volgers
3
Documenten
7581
Laatst verkocht
4 dagen geleden
Expert1

Welcome to Expert1 – Your Trusted Study Partner! Struggling to prepare for exams or ace your coursework? At Expert1, I provide top-tier, exam-ready study materials designed to help you succeed with confidence. All notes are created with clarity, precision, and a deep understanding of the curriculum to ensure you save time and score high. What You’ll Find Here: High-quality summaries and exam packs Past paper solutions with detailed explanations Notes aligned with your syllabus (A-levels, university, etc.) Resources from top-performing students Trusted by hundreds of students to boost their grades!

Lees meer Lees minder
4,4

7 beoordelingen

5
6
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen