Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM QUESTIONS WITH VERIFIED SOLUTIONS GRADED A+ LATEST VERSION

Beoordeling
-
Verkocht
-
Pagina's
36
Cijfer
A+
Geüpload op
30-11-2025
Geschreven in
2025/2026

BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM QUESTIONS WITH VERIFIED SOLUTIONS GRADED A+ LATEST VERSION Backflow in a water supply can be caused by (A) Backpressure only (B) A Barometric Loop (C) Backsiphonage only (D) Backpressure and Backsiphonage --CORRECT ANSWER--Backpressure and Backsiphonage A BPAT tester is required to report test information on the proper forms to the (A) Administrative authority (B) Manufacturer's Rep (C) EPA (D) None of the above --CORRECT ANSWER--Administrative authority The relief valve opens when closing #2 shut off valve on a RP What is the most probable cause Page 2 of 36 (A) #1 Shut off valve is open (B) #2 Shut off valve is open (C) #1 check is fouled open (D) Shut off is leaking --CORRECT ANSWER--#1 check is fouled open

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

BACKFLOW PREVENTION ASSEMBLY TESTER
PRACTICE EXAM QUESTIONS WITH VERIFIED
SOLUTIONS GRADED A+ LATEST VERSION



Backflow in a water supply can be caused by



(A) Backpressure only

(B) A Barometric Loop

(C) Backsiphonage only

(D) Backpressure and Backsiphonage --CORRECT ANSWER--Backpressure
and Backsiphonage



A BPAT tester is required to report test information on the proper forms to the



(A) Administrative authority

(B) Manufacturer's Rep

(C) EPA

(D) None of the above --CORRECT ANSWER--Administrative authority



The relief valve opens when closing #2 shut off valve on a RP What is the most
probable cause



Page 1 of 36

,(A) #1 Shut off valve is open

(B) #2 Shut off valve is open

(C) #1 check is fouled open

(D) Shut off is leaking --CORRECT ANSWER--#1 check is fouled open



When field testing the #1 Check of a RP the differential pressurw shouid be



(A) Greter than or equal to 5.0 psid

(B) 3.0 psid greater than the relief valve opening point

(C) 1.0 psid in the directiom of flow

(D) Less than 5.0 psid --CORRECT ANSWER--Greter than or equal to 5.0 psid



When testing a SVB what is the firsrt test being performed



(A) The air inlet opening point

(B) The static pressure across the check valve

(C) To verify the #2shut off hold tight

(D) To check if the SVB hold water --CORRECT ANSWER--The static
pressure across the check valve



When testing a PVB the air inlet opens upon closing the #1 shut off valve What
is the most probable cause


Page 2 of 36

,(A) Leaking #2 shut off valve

(B) Leaking #1 shut off valve

(C) Fouied air inlert

(D) Fouied check valve --CORRECT ANSWER--Leaking #2 shut off valve



A 2" AVB when used on irrigation systemsterm-15 shall be instilled



(A) 6" above all downstream piping

(B) 18" above all downstream piping

(C) 24" above all downstream piping

(D) 27 3/4" above all downstream piping --CORRECT ANSWER--6" above all
downstream piping



What causes the relief valief valve to close on a RPZ?



(A) Reilef valve spring pressure

(B) Supply side water pressure

(C) Pressure differential between Check #1 and Check #2

(D) All the above --CORRECT ANSWER--Supply side water pressure




Page 3 of 36

, When testing a RP instialled in vauil the relief valve opening point falls to zero
What is most probabie cause



(A) The relief valve is stuck shut

(B) #1 check is fouled

(C) the #2 shut off leaks by

(D) Installed improperly --CORRECT ANSWER--Installed improperly




When field testing the DC the #1 check static differential pressure is found to be
0.0 psid What is the most probable cause



(A) Fouied #2 Check

(B) Leaking #2 shut off

(C) Fouled #1 check

(D) Leaking #1 shut off --CORRECT ANSWER--Fouled #1 check



The critical level for checking the air inlet of the PVB is



(A) At the air inlet

(B) At #1 shut off

(C) At #1 test cock


Page 4 of 36

Geschreven voor

Vak

Documentinformatie

Geüpload op
30 november 2025
Aantal pagina's
36
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€23,99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
TESTBANKNURSEHUB
4,0
(2)

Maak kennis met de verkoper

Seller avatar
TESTBANKNURSEHUB Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
8
Lid sinds
8 maanden
Aantal volgers
0
Documenten
3065
Laatst verkocht
1 week geleden
your document plug

I offer all types of documents notes, exams and study guide practice exams. Feel free to contact me for any clarification and document prices.

4,0

2 beoordelingen

5
0
4
2
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen